KROHNE OPTIWAVE 7300 C Handbook page 58

Non-contact radar (fmcw) level meter for liquids
Hide thumbs Also See for OPTIWAVE 7300 C:
Table of Contents

Advertisement

OPERATION
6
Menu
No.
A.1.3
58
Step
Function
3A
Application Type
4A
Stillwell Diameter
4B
Stillwell Height
5
Blocking Distance
6
Settings summary
7
Current changes
must be saved or
cancelled before
proceeding
Empty Spectrum
1
Do you have a
completely filled
tank?
Function description
The conditions in which
the device is used. If the
surface of the product is
flat, select "Storage". If
the surface of the
product is disturbed,
select "Process". If the
surface of the product is
agitated with vortexes
and foam, select
"Agitator". If the device
is installed in a still well,
select "...+Stillwell".
The conditions in which
the device is used. For
free air applications
only. If the surface of the
product is flat, select
"No Disturbance". If the
surface of the product is
disturbed, select
"Medium Disturbance".
If there are bubbles on
the surface of the
product and also
vortexes and foam,
select "Heavy
Disturbance".
The inner diameter of
the stillwell. Step 4 is
available if you set
"...+Stillwell" in step 3.
The height of the
stillwell. Step 4 is
available if you set
"...+Stillwell" in step 3.
A zone given by the user
where it is not possible
to measure. We
recommend a blocking
distance at least
100 mm / 4¨ below the
antenna.
Fixed and moving
objects in the tank cause
interference signals.
Put them through this
filter to correctly
measure the tank
contents.
If the tank is full, it is not
possible to complete
this procedure. The tank
must be partially filled
or empty.
www.krohne.com
OPTIWAVE 7300 C
Selection list
Process, Storage,
Agitator,
Process+Stillwell,
Storage+Stillwell,
Agitator+Stillwell
No Disturbance,
Medium
Disturbance, Heavy
Disturbance
min-max:
8...200 mm /
0.31...7.88¨
min-max:
0...80 m / 0...262 ft
min-max:
antenna extension
(C.1.6) + 50 mm /
2¨...tank height
(C.1.2)
1
Save, Cancel
3
Yes, No
04/2011 - 4000172404 - HB OPTIWAVE 7300 R06 en
Default
Process or
Process+
Stillwell
No
Disturbance
100 mm /
3.94¨
10 m /
32.81 ft
2
Yes

Advertisement