Sharp MD-E9000H Service Manual page 77

Md compact component system
Hide thumbs Also See for MD-E9000H:
Table of Contents

Advertisement

IC1 VHiLC78645NE1: CD Servo (LC78645NE) (2/2)
Terminal Name Input/Output Setting in Reset
Pin No.
44
RVSS
45*
RCHO
46
RVDD
47
XVDD
48
XOUT
49
XIN
50
FSX/16MIN
Input/Output
51
XVSS
52*
C2F
53*
EFLG
54*
16MOUT
55
ASLRCK
56
ASDACK
57
ASDFIN
58
LRCK
59
BCK
60
DATA
61
CE
62
CL
63
DI
64
DO
65
*WRQ
66
*RES
67
DRF
68
VDD5
69
VSS
70
CONT3
Input/Output
71
CONT2
Input/Output
72
CONT1
Input/Output
73
PDO1
74
PDO2
75
VVSS
76
PCKIST
77
VVDD
78
FR
79
LDS
80
LDD
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Be sure to supply the same potential to each power terminal. (VVDD, ADAVDD, VDD, LVDD, RVDD, XVDD)
Terminal witch is controlled by the power terminal (VDD5 V) for a microcomputer interface :
CE (61 pin), CL (62 pin), DI (63 pin), DO (64 pin), WRQ (65 pin), RES (66 pin), DRF (67 pin)
All manuals and user guides at all-guides.com
Right channel
Output
LVDD /2
D/A converter
Input
Input
Crystal
Output
Oscillator
Input
Input
7.35 kHz Synchronization signal monitor port.
or Clock input port for Digital filter & D/A
Crystal
Oscillator
Output
H
C2 FLAG monitor port.
Output
L
C1, C2 error corrected monitor port.
Output
Clock
16.9344 MHz output port.
Input
Input
Anti-shock
Input
Output
L
Output
L
Digital data
Output
L
Input
Input
Microcomputer
Input
Interface
Output
(H)
Output
H
Input
Chip reset signal input port.
This port must be set LOW after first applied power on.
Output
L
Focus detection output port.
Input
Power supply for Microprocessor.
GND for digital circuit. Must be connected to 0 V.
Input
General purpose port 1.
Input
General purpose port 2.
Input
General purpose port 3.
Output
Output
Input
Input
Input
Input
Input
LASER power detected signal input port.
Output
LASER power control signal output port.
Function
GND for Right channel. Must be connected to 0 V.
Right channel output.
Power supply for Right channel.
Power supply for crystal oscillator.
Connected for the 33.8688 MHz crystal oscillator cement.
GND for crystal oscillator. Must be connected to 0 V.
Word clock input port.
(If this port does not use, must be connect to 0 V.)
Bit clock input port.
(If this port does not use, must be connect to 0 V.)
Left/Right channel data input port.
(If this port does not use, must be connect to 0 V.)
Word clock output port.
Bit clock output port.
Left/Right channel data output port.
Chip enable signal input port.
Data transfer clock input port.
Data input port.
Data output port. (N-ch. open drain output.)
Interruption signal output.
Controlled with serial data command from micro-
computer. When not used, General purpose input/
output terminal 7. Set it as the input terminal and open
it by connecting to 0 V, or set it as the output terminal
and open it.
Internal VCO control phase comparator output port 1.
Internal VCO control phase comparator output port 2.
GND for internal VCO. Must be connected to 0 V.
PLL
PDO output current adjustment resistor connection port.
Power supply for internal VCO.
VCO frequency range adjustment port.
– 77 –