Parts list
№ Name
1
Operation light
2
Welding current adjustment
3
Error light
4
Release time adjustment
Positive output terminal
– TIG: to connect TIG work piece cable
5
– MMA: to connect electrode holder or work
piece cable

Installation

If you want to use a cable that is longer than the one supplied, use one with a larger cross-section.
Thus, you can avoid voltage drops. If the torch cable or the electrode holder cable is too long, it may
interfere with the operation of the arc and other functions of the system. For this reason, we recom-
mend that the user stick to the accessories supplied to ensure propre function of the device.
Connecting the input cable
Each welding machine has a power cord. During the connection of that to the power supply
you have to make sure that it matches the input voltage of the device (230 V). If the mains ca-
ble of 230 V DC is connected to a 380 V AC connection, the overvoltage protection is trig-
gered. In this case, switch off the power supply first and then connect the welding machine to
a suitable mains connection (230 V). You can now put the welding machine into operation.
Make sure that the power cord is securely connected to the machine and check whether the
line voltage is correct.
© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
№ Name
2-pole connector, control cable for TIG
6
standard welding torch
Quick connector for TIG welding torch gas
7
conduct
Negative output terminal
– TIG: to connect TIG work piece cable
8
– MMA: to connect electrode holder or work
piece cable
9
MMA/TIG switch