Summary of Contents for WilTec TIG180

  • Page 1 Operation Manual Arc Welder 61707, 61708 Illustration similar, may vary depending on model Please read and follow the operating instructions and safety information prior to initial operation. Technical changes reserved! Illustrations, functional steps and technical data may deviate insignificantly due to continuous further developments.
  • Page 2 The information contained in this document may alter at any time without prior notice. No part of this document may be copied or otherwise duplicated without prior written consent. All rights reserved. WilTec Wildanger Technik GmbH cannot be held liable for any possible mistakes in this operating manual, nor in the diagrams and illustrations shown.
  • Page 3 Only use the device according to the intended use defined in this manual. The welding machine must NOT be used • in rooms without sufficient ventilation, • in damp or wet zones, • in explosive zones, © by WilTec Wildanger Technik GmbH Item 61707, 61708 Page 3 http://www.WilTec.de http://www.aoyue.eu 2021-1 http://www.teichtip.de...
  • Page 4 Avoid any direct contact with the welding circuit; no-load voltage forming between the electrode holder and earth terminal can be dangerous. • Do not store or use the device in damp or wet zones or in the rain. © by WilTec Wildanger Technik GmbH Item 61707, 61708 Page 4 http://www.WilTec.de http://www.aoyue.eu...
  • Page 5 Make sure that vapours and gases can escape through suitable vents. However, do not take in oxygen. This would increase the risk of fire. © by WilTec Wildanger Technik GmbH Item 61707, 61708 Page 5 http://www.WilTec.de...
  • Page 6 Completely disconnect the welding machine from the power supply before performing maintenance works. The machine is largely mainte- nance-free. However, the following works should be performed: © by WilTec Wildanger Technik GmbH Item 61707, 61708 Page 6 http://www.WilTec.de...
  • Page 7 No-load loss (W) Pilot arc model Efficiency (%) Power factor 0.93 0.93 Insulation class Isolation class IP21S IP21S Weight (㎏) Total dimensions (㎜) 465×255×330 465×255×330 © by WilTec Wildanger Technik GmbH Item 61707, 61708 Page 7 http://www.WilTec.de http://www.aoyue.eu 2021-1 http://www.teichtip.de...
  • Page 8: Installation

    (230 V). You can now put the welding machine into operation. • Make sure that the power cord is securely connected to the machine and check whether the line voltage is correct. © by WilTec Wildanger Technik GmbH Item 61707, 61708 Page 8 http://www.WilTec.de http://www.aoyue.eu...
  • Page 9 The purpose of the jacket is to protect the weld pool from harmful air ingress and to stabilise the arc. On the other hand, a slag forms that protects and shapes the weldseam. Al- most all metals can be welded with electrode welding. © by WilTec Wildanger Technik GmbH Item 61707, 61708 Page 9 http://www.WilTec.de...
  • Page 10 Screw the union nut of the gas hose connection to the “outlet side of the pressure reducer.” • Gas-tighten the union nut of the shielding gas line to the gas connection on the back of the welding machine. © by WilTec Wildanger Technik GmbH Item 61707, 61708 Page 10 http://www.WilTec.de http://www.aoyue.eu...
  • Page 11 The weldseam is adjusted with the welding current regulator. Note: Do not touch any cables or plugs while the machine is operating, as this can result in injuries or damages to the machine. © by WilTec Wildanger Technik GmbH Item 61707, 61708 Page 11 http://www.WilTec.de http://www.aoyue.eu...
  • Page 12: Troubleshooting

    Several connectors have bad contact, especially inserts, etc.; check or out of potentiometer them. control Excessive weld spat- ter/incorrect electrode Electrode is connected incorrectly; replace the earth and handle cables. polarity © by WilTec Wildanger Technik GmbH Item 61707, 61708 Page 12 http://www.WilTec.de http://www.aoyue.eu 2021-1 http://www.teichtip.de...
  • Page 13 German law related to electrical and electronic equipment and appliances. All WilTec electric devices that fall under the WEEE directive are labelled with the symbol of a crossed-out wheeled rubbish bin. This symbol indicates that this electric device must not be disposed of with the domestic waste.

This manual is also suitable for: