Advanced Models

Models
Advanced
Advanced
Models
Motor Part
Part No.
No.
Motor
Motor
Part
No.
Series
Series
Series
EM0012
C
EM0015
C
EM0022
C
EM0025
C
0359
0359
0359
Figure 3 Advanced Motor Identification Label
List of of of Standards
Standards
List
List
Standards
• IEC 60079–0: 2011 (Ed. 6)
• IEC 60079–1: 2014 (Ed. 7)
• IEC 60079–11: 2011 (Ed. 6)
• EN 60079–0: 2012
• EN 60079–1: 2014 (Ed. 7)
• EN 60079–11: 2012
• FM 3600:2011
• FM 3610:2010
• FM 3615:2006
• FM 3810:2005
• CSA C22.2 No. 0.4:2004 (R2009)
Specific Conditions
Conditions of of of Use:
Use:
Specific
Specific
Conditions
Use:
1. Consult the manufacturer if dimensional
information on the flameproof joint is necessary.
2. Consult the manufacturer for genuine
replacement fasteners. M8 x 30 socket-head
cap screws of Class 12.9 steel or better with a
minimum yield strength of 1100 MPa (160,000
psi) are acceptable alternatives.
3A2526L
All manuals and user guides at all-guides.com
Horsepower
Horsepower
Horsepower
1
1
2
2
II 2 (1) G
Ex db [ia] IIA T6 0°C≤Ta≤40°C
FM12ATEX0067X
IECEx FMG 12.0028X
Maximum
Maximum
Maximum Force,
Force,
Force, lbf lbf
1400 (6227)
1400 (6227)
2800 (12455)
2800 (12455)
For Class I, Div. 1, Group D T6.
Class 1, Zone 1, AEx db [ia] IIA T6 0°C≤Ta≤40°C
Ex db [ia] IIA T6 0°C≤Ta≤40°C
• CSA C22.2 No. 0.5:82 (R2008)
• CSA C22.2 No. 30:M86 (R2007)
• CSA C22.2 No. 157–92 (R2006)
• CAN/CSA-E60079–0:2011
• CAN/CSA-E60079–1:2011
• CAN/CSA C22.2 No. 1010.1:2004
• CAN/CSA-E60079–11:2011
• ANSI/ISA 60079–0:2009
• ANSI/ISA 60079–1:2009
• ANSI/ISA 60079–11:2011