Pulsar HADOC 8012C Quick Start Manual

Buffer switch mode power supply unit with technical outputs

Advertisement

Quick Links

HADOC 8012C
v.1.0
HADOC 13,8V/8A/17Ah/OC
Buffer switch mode power supply unit
with technical outputs
EN
Edition: 3 from 10.10.2014
Supercedes edition: 2 from 05.06.2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HADOC 8012C and is the answer not in the manual?

Questions and answers

Summary of Contents for Pulsar HADOC 8012C

  • Page 1 HADOC 8012C v.1.0 HADOC 13,8V/8A/17Ah/OC Buffer switch mode power supply unit with technical outputs Edition: 3 from 10.10.2014 Supercedes edition: 2 from 05.06.2014...
  • Page 2: Table Of Contents

    GREEN POWER plus www.pulsar.pl HADOC8012C Features:   FAC technical output indicating AC power loss 13,8V/8A uninterruptible power supply – OC and relay type  fitting battery: 17Ah/12V   FPS technical output indicating PSU failure wide range of mains supply: 176÷264V –...
  • Page 3: Block Diagram

    GREEN POWER plus www.pulsar.pl HADOC8012C - HADOC8012C + LB8 8x1A (AWZ580 or AWZ579) + 7Ah Buffer power supply HPSBOC 13,8V/12V/8x1A/7Ah. - HADOC8012C + RN500 (13,8V/12V) + LB8 5x1A (AWZ580 or AWZ579) + 7Ah HPSBOC 13,8V/2x5V÷7,4V/2x2A/7Ah. Buffer power supply - HADOC8012C + 2 x DCDC20 (2x5V÷7,4V/2x2A) + 7Ah HPSBOC 13,8V/5V÷7,4V/4x0,5A/7Ah.
  • Page 4: Description Of Psu Components And Connectors

    GREEN POWER plus www.pulsar.pl HADOC8012C Fig. 2. The view of the PSU. Description of PSU components and connectors (tab.2, fig.3). lement no. Description [Fig. 3] PSU module TAMPER, contact, sabotage protection (NC) Tab.2. Output terminals of the PSU. Fig.3. The view of the PSU.
  • Page 5 GREEN POWER plus www.pulsar.pl HADOC8012C Electrical parameters (tab. 3) 176÷264V AC Mains supply Current up to 1,5A@230VAC Supply power 120W max. Efficiency 11V÷ 13,8V DC – buffer operation Output voltage 9,5V÷ 13,8V DC – battery-assisted operation <30°C Output current t 8A + 0,5A battery charge - see chart 1 =40°C...
  • Page 6: Installation

    GREEN POWER plus www.pulsar.pl HADOC8012C Operating parameters (tab.6) -10ºC...+40ºC (see: chart 1) Operating temperature Storage temperature -20ºC...+60ºC Relative humidity 20%...90%, without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insulation unacceptable Vibrations and impulse waves during transport According to PN-83/T-42106 Chart 1.
  • Page 7: Operating Status Indication

    GREEN POWER plus www.pulsar.pl HADOC8012C The shock protection circuit shall be performed with a particular care, i.e. the yellow and green wire coat of the power cable shall stick to one side of the terminal - marked with ‘ ‘ symbol on the PSU enclosure. Operation of the PSU without the properly made and fully operational shock protection circuit is UNACCEPTABLE! It can cause a device failure or an electric shock.
  • Page 8: Operation And Use

    GREEN POWER plus www.pulsar.pl HADOC8012C CAUTION! In the Fig.2. the set of contacts shows a potential-free status of the relay which corresponds to a state with no DC power (PSU failure).  FLB – technical output indicating battery voltage: > 11,5V) the output is connected to ground (L level – 0V). In case - OC type output.
  • Page 9 GREEN POWER plus www.pulsar.pl HADOC8012C...
  • Page 10 GENERAL WARRANTY CONDITIONS 1. Pulsar K. Bogusz Sp.j. (the manufacturer) grants a four-year warranty for the equipment, counted from the device’ production date. 2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects,...

Table of Contents