Detachment of impeller
1
Fasten the exchange unit firmly to a vice.
2
Unscrew the cap screw socket head (914.11) of the impeller (230.11).
3
Prevent the shaft (210.31) from rotating at the coupling (840.51) end.
4
Detach the impeller by turning it counter-clockwise. Push e.g. pieces of wood between the impeller vanes to
ease the detachment. Never use metal bars or the like, because they might damage the impeller vanes. Fig.
2.
3.2 Reassembly
Installation of impeller
The socket head screw (914.11) must be secured to avoid loosening of the impeller.
When installing the impeller and the sideplate, replace all O-rings with new ones.
ORIGINAL INSTRUCTION
USER'S MANUAL – AHLSTAR
Corrective maintenance
SPP id: Version 14 > / 140901 / Replaces 140530 / en / N32198 / 3 / Page 5 (27)
250