Page 1
Thank you for purchasing the BPBIO750. This user’s manual describes all the features of the BPBIO750. Please read before use and keep it in a safe place. By following the manual instructions, you will be able to use the BPBIO750 more safely and effectively.
Page 2
Please note the important information below before reading this manual. Warning Failure to observe these precautions can result in personal injury or damage to the equipment. Caution Failure to comply with safety precautions can damage the equipment. Note Reading the notes can help you get the most out of your device. Avertissement Le non-respect de ses précautions peut causer des blessures ou des dommages à...
Contents I. BPBIO750电子血压计的安装 I. BPBIO750 Installation A. 产品组成 A. Product Components B. 操作环境 B. Operating Environment C. 安装指南 C. Installation Instructions D. 打印纸安装和替换 D. Loading and Reloading Printer Paper E. 袖带更换 E. Replacing Cuff Cover F. 设置菜单 F. Setup G. 连接InBody人体成分分析仪 G. Connecting to InBody H. 维护 H. Precautions for Maintenance II.
Page 4
BPBIO750_manual_다국어 합본_F_210517.indd 4 BPBIO750_manual_다국어 합본_F_210517.indd 4 2021-05-21 오전 10:41:14 2021-05-21 오전 10:41:14...
Page 5
BPBIO750 User's Manual English BPBIO750_manual_다국어 합본_F_210517.indd 5 BPBIO750_manual_다국어 합본_F_210517.indd 5 2021-05-21 오전 10:41:14 2021-05-21 오전 10:41:14...
I. BPBIO750 Installation A. Product Components The BPBIO750 consists of the following components. Make sure all of the components are present. * Please check each component for damage prior to installation. Standard Components The BPBIO750 Power cable 110V or 220V (AC 250V 10A 1.8m (70.9 in.)) 1 EA Printer paper 2 EA User’s manual...
Atmospheric pressure range 70 to 106 kPa C. Installation Instructions 1. Open the BPBIO750 box and remove the packing pads. Remove the protective vinyl on the BPBIO750 and take it out of the box. Remove the packing material. Protective vinyl Packing pads SYS.
Page 8
2. Place the equipment on a solid table that can withstand the weight of the BPBIO750 (approx. 7.1kg (15.65lb)). If using the optional BPBIO750 desk, align the desk fixing grooves on the bottom of the BPBIO750 with the grooves on the desk and secure them with the two fixing screws. SYS. DIA. Desk fixing grooves Desk grooves Place your elbow on the elbow point. Press the START button. Do not move during the measurement.
Page 9
• Do not disassemble the equipment arbitrarily. This may cause electric shock or injury, product malfunction, and/or inaccurate results. Unauthorized disassembly will void the manufacturer’s warranty. • Do not let the BPBIO750 touch other electronic devices when turned on. This may cause electric shock. Caution •...
Page 10
4. Use the anti-theft groove to prevent theft. * Theft protection cable is sold separately. 5. Turn the BPBIO750 on by pressing the power switch located on the back of the device. Power switch 6. When powered on, the BPBIO750 will automatically calibrate and display the following screen.
D. Loading and Reloading Printer Paper 1. Press the button shown below to open the cover while the BPBIO750 is turned on. PUSH 2. Insert the printer paper in the direction as shown below. After inserting the printer paper, let a certain amount of paper come out of the cover, then close it to complete the installation.
E. Replacing Cuff Cover The cuff cover of the BPBIO750 should be replaced periodically for sanitary purposes. Follow the guide below to replace the cuff cover. Print 1. Remove the front cover of the BPBIO750 by pushing downward, and loosen the screw with a screwdriver. Remove the ring on the front of the BPBIO750 by pulling it forward. SYS. DIA. SYS. DIA. Screw...
Page 13
• Les résultats de la pression artérielle pourraient être faussés si la ligne de couture n’est pas placée vers le bas. Print 5. Reattach the front and rear rings to the BPBIO750 and secure them with the screws. Close the front cover of the BPBIO750. Screw...
F. Setup Setup consists of time settings, sound settings, Result Sheet printing, pressure unit setting, and communication settings. 1. Configuring Setup 1) When the ' ' and 'Print' buttons are pressed and held simultaneously for 2 seconds while on the home screen, ' ' (Time setting) will blink.
Page 15
SYS. DIA. 2. Setup Example Place your elbow on the elbow point. Press the START button. The following is an example showing how to change the automatic Result Sheet printing option to manual Do not move during the measurement. printing option. SYS.
Page 16
YY / MM / DD Date output format MM / DD / YY DD / MM / YY Pressure unit mmHg InBody Communication 3-line automatic output (vertical) * F13-F18 function not available Type of Result Sheet 3-line automatic output (horizontal)
Page 17
Output of additional blood pressure Blood Pressure information on the Result Sheet Knowledge Not used Result Pulse Evelope output on the Result Sheet Sheet Pulse Evelope item Not used Customized logo on the Result Sheet Logo Not used Elbow sensor is functional Setting up the Elbow Sensor Elbow sensor is disabled...
* Serial cable is sold separately. 1. Turn off the BPBIO750. 2. Connect the serial cable to the RS232C (9-pin serial) connection terminal located on the back of the BPBIO750. Connect the other end of the serial cable to the serial connection terminal on the InBody device.
• Make sure the power cord is not a tripping hazard. The BPBIO750 calibrates automatically when it is turned on, but it may be necessary for a specialist to inspect the device once every two years to maintain its performance and safety. If an error message appears during calibration, please contact product support.
Blood Pressure Test A. Preparatory Steps Caution • Examinee should rest at least 5 to 10 minutes before the test. • Do not roll up the examinee's sleeve; instead, remove thick clothing • Examinee should sit up straight in the chair. • Insert the examinee's arm until the elbow is positioned in the elbow groove. •...
Page 21
• If an emergency occurs during the test, press the buttons on the bottom (toward the front) of the BPBIO750 - the cuff will quickly release. Attention • Si une urgence survient pendant le test, appuyez sur le bouton Arrêt/Marche ou Arrêt d’urgence, en bas sur le devant du BPBIO750.
Page 22
* Please consult with your physician for accurate diagnosis. 8. Others The Start/Stop button on the rear of the BPBIO750 also allows you to initiate the test, which can be useful for the administrator to conduct the test from the back of the device.
C. Test Posture For the most accurate results, get into the proper posture for testing. * The BPBIO750 allows examinees to measure with either arm. Blood Pressure Cuff Adjust the height of the chair so the upper part of the right arm and the heart are horizontal with each other.
III. Transportation and Storage A. Cautions during Transportation To transport the BPBIO750 securely, two people should keep the equipment parallel to the ground. Caution When transporting the equipment alone, keep the device horizontal. • Attention • Lorsque vous transportez l'équipement seul de façon inévitable, soulevez-le en le maintenant horizontal comme suit.
B. Repacking Instructions 1. Turn off the BPBIO750. 2. Remove all connected cables and put the packing material into the BPBIO750. Wrap package in protective vinyl and insert the packing pads into the box. Package protective vinyl Packing material Packing pads Caution • When repacking the equipment, use the protective packing material included with the device.
· Make sure you are using the power cable (AC 250V 10A) provided by InBody. <110V> <220V> · Issue may occur when the fuse is blown. Replace the fuse by following the...
Page 27
Note • Error messages and collateral like Result Sheets containing errors can be used to assist with A/S request; please record or keep these items. Attention • InBody Co, Ltd se décharge de toute responsabilité en cas de problème si la maintenance et l’inspection de votre appareil ne sont pas effectuées par un technicien accrédité ou un employé de la société. Remarque • Puisque les messages d’erreurs et/ou les fiches de résultats erronés peuvent être utilisés pour le service après-vente, veuillez en prendre note dans un registre et/ou garder les copies en filière.
* The blood pressure value will be measured higher. Remove thick clothing. Do not roll up sleeves. · The examinee may have tested without resting beforehand. Take the test after resting at least 5 minutes. * The first reading may be high even after taking a sufficient rest. · Do not talk or move during the test. * Blood pressure may vary throught the day. InBody recommends testing at different times of the day. BPBIO750_manual_다국어 합본_F_210517.indd 28 BPBIO750_manual_다국어 합본_F_210517.indd 28 2021-05-21 오전 10:41:27 2021-05-21 오전 10:41:27...
Page 29
1 hour before testing, or measure with another arm. · Can results vary depending · The BPBIO750 can operate at 10-40ºC (50-104ºF). However, if the examinee on the testing environment feels that the temperature is too low or high, the blood vessels expand or contract, which will affect the blood pressure results. It is recommended to test...
Others * The BPBIO750 was manufactured according to the quality control procedure of InBody Co., Ltd. InBody complies with ISO9001 and ISO13485, which are international quality management systems. * This equipment satisfies the common standard for electrical and mechanical safety of medical devices and the common standard for the safety of medical devices. A. Exterior and Functions Below is a list of BPBIO750 components and its function.
B. Safety Information Warning • If this equipment has been altered, it must be inspected to ensure that it can be used safely. • Results can only be interpreted by experienced healthcare professionals. It cannot be used for diagnosis, medication, or other treatments performed at the consumer’s discretion without a doctor ̓ s prescription. Caution •...
Safety Symbols Danger: high voltage Warning / Caution Note BF-type equipment Power on Power off Etc. Symbols European Conformity Serial number 0120 0120 0120 Manufacturer Alternating current Authorized representative in the Operating instructions 0120 EUROPEAN COMMUNTY NRTL mark (MET) * MET symbols apply to products sold in the United States and Canada. C. Product Classification Oscillometric multi-functional electronic blood pressure monitor •...
D. Product Specifications Test Instructions Oscillometric Test range Pressure: 0 to 300 mmHg Pulse: 30 to 240 bpm Degree of precision Pressure: ± 2mmHg Pulse: Within ± 1.5% Test result Systolic blood pressure, diastolic blood pressure, pulse rate, pulse pressure, mean arterial pressure, rate pressure product Test Time Approx.
E. EMC Declaration Test Name IEC 60601- Ref. Standard Ports to Test AC Mains Volt- Test Level Required Notes 4th Edition Mains terminal CISPR 100V, 50Hz AC Mains disturbance voltage 11:2015/ 100V, 60Hz Group 1, AMD2:2019 120V, 60Hz Class B 220V, 60Hz 230V, 50Hz CISPR...
Page 35
100V, 50Hz Power-frequancy IEC 61000-4- Enclosure 100V, 60Hz Magnetic Field 8:2009 120V, 60Hz 30 A/m 220V, 60Hz 50 Hz & 60 Hz 230V, 50Hz Battery AT 0°, 45°, 0% UT for 0.5 cycle 90°, 135°, 180°, 225°, 270°, 315° 0% UT for 1 cycle AT 0°, 180°...
Page 36
Electromagnetic immunity The [Model name] is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. Portable RF communications equipment should be used no closer than 30 cm (12 inches) to any part of the [Model name]. Otherwise, degradation of the performance of this equipment could result.
Page 37
BPBIO750 使用手册 中國語 BPBIO750_manual_다국어 합본_F_210517.indd 37 BPBIO750_manual_다국어 합본_F_210517.indd 37 2021-05-21 오전 10:41:31 2021-05-21 오전 10:41:31...
Page 69
BPBIO750_manual_다국어 합본_F_210517.indd 69 BPBIO750_manual_다국어 합본_F_210517.indd 69 2021-05-21 오전 10:41:50 2021-05-21 오전 10:41:50...
Page 70
BPBIO750_manual_다국어 합본_F_210517.indd 70 BPBIO750_manual_다국어 합본_F_210517.indd 70 2021-05-21 오전 10:41:50 2021-05-21 오전 10:41:50...
Page 71
Reproduction, adaptation, or translation of this manual is prohibited without prior written consent from InBody Co., Ltd. under the copyright laws. This user manual may be printed incorrectly and subject to change without notice. InBody Co., Ltd. shall not be liable for any errors, incidental, or consequential damages that occurred by not complying with the content of the User’s Manual.
Need help?
Do you have a question about the BPBIO750 and is the answer not in the manual?
Questions and answers