JVA MB8 Installation And User Manual

JVA MB8 Installation And User Manual

Electric fence energiser

Advertisement

JVA Electric Fence Energiser
Installation and User Manual
(MB8, MB12, MB16, SV5, SV10)
J VA T E CH N O LO G I E S
www.jva-fence.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MB8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JVA MB8

  • Page 1 JVA Electric Fence Energiser Installation and User Manual (MB8, MB12, MB16, SV5, SV10) J VA T E CH N O LO G I E S www.jva-fence.com...
  • Page 2: Table Of Contents

    Other ..... . .8 3 JVA Models and Features . . . . . . . . . . . . . . . . 9 Features .
  • Page 3 7 Troubleshooting Energiser Problems . . . . . . 26 Moisture and Ants ....26 Lightning ....26 Flat Batteries .
  • Page 4: Introduction

    INTRODUCTION Congratulations on your choice of a JVA Energiser. In choosing to purchase a JVA product you have opted for the highest quality in electric fencing. Please read this manual entirely before installing or operating your new energiser. All JVA products offer a three-year warranty against faulty components and workmanship but excludes environmental extremes (i.e.
  • Page 5: Important Notes

    (eg. 1.8m Galvanized earth rods) driven into the earth to a depth of at least 1.2m. Three earthing rods are recom- mended for customers purchasing the MB8, MB12, or MB16. Addi- tional earth connections may be required at the energiser or along the fence in poor soil conditions.
  • Page 6: Power Supply Options

    POWER SUPPLY OPTIONS The JVA MB electric fence energisers can be powered from a number of power sources. a. 12V external battery (not supplied) b. 12V external battery with solar panel (not supplied) c. 110/240Vac via power pack (supplied with MB models only) The JVA SV series of electric fence energisers are fully self contained solar powered energisers.
  • Page 7: Auto-Sync Tm

    AUTO-SYNC TM Auto-Sync™ is a new method of synchronising electric fence energisers patented by Pakton Group Pty Ltd. Auto-sync detects when something or someone touches the wires from two different electric fences, and synchronises the output pulses so that the potentially dangerous condition of receiving more than one pulse per second is avoided.
  • Page 8: Solar Panels

    RECHARGEABLE BATTERIES 1. The SV5/SV10 contains a rechargeable sealed lead acid (SLA) battery, while other JVA MB energisers are compatible with lead acid batteries. SLA battery life is shortened considerably if it is a. left in a discharged state or;...
  • Page 9: Jva Models And Features

    JVA MODELS AND FEATURES FEATURES MB12 MB16 SV10 Mains powered Battery powered Digital control “Smooth” wave shape Power on demand LCD showing kV and Stored Energy Ant & moisture protec- tion UV stable enclosure Overload indication (Audible and Visible) Lightning protection...
  • Page 10 0.9 A 1.25 A 1.6 A 67mA 84mA 12.5Vdc Warranty 3 Years 3 Years 3 Years 3 Years 3 Years Power adapter includ- ed (24Vdc) Battery leads included Audible alarm Auto Recover Auto-Sync™ Bi-Polar output Page 10 © JVA Technologies. www.jva-fence.com...
  • Page 11 • Battery life maximization works by slowing the frequency of high volt- age pulses just before the battery dies to keep the energiser going for as long as possible without damaging the battery. • The over discharge battery protection will stop the energiser when the battery is flat and flash the status LED twice each second.
  • Page 12: Specifications

    © JVA Technologies. www.jva-fence.com...
  • Page 13 Symbols • # - No load, actual voltage on a short fence can be as high as 10kV • ~ - Current drain rating is for a 12.5V power source. Current drain will vary with voltage. • ^ - Recommended solar panel sizes based on the number of sun hours/ day a region receives.
  • Page 14: Jva Models And Features

    JVA MODELS AND FEATURES 1. Status indicates fence overload or internal energiser fault (red LED) 2. Energiser On and OK indicator (green LED) 3. High Power fence connection terminal 4. Low Power fence connection terminal (Not on SV5/SV10) 5. Ground/Earth return connection terminal 6.
  • Page 15: Fence Connectors

    7. Model number panel (both units) 8. LCD – Liquid Crystal Display 9. 12 volt battery clips (black = negative, red = positive) (Not on SV5/SV10) 10. ON/OFF switch 11. Solar Panel Bracket (SV5/SV10 Only) 12. Solar Panel (SV5/SV10 Only) FENCE CONNECTORS High Power Low Power...
  • Page 16: Power Button

    Flashes with each pulse to show the unit is on and operating correctly. LCD Screen - The LCD shows: • Operating Status information • Battery voltage and capacity • Output Voltage (Kilo volts) • Stored Energy (Joules) • Error codes (See section 6.5) Page 16 © JVA Technologies. www.jva-fence.com...
  • Page 17: Battery At Half Capacity

    Status Symbols (model dependant): • Wi-Fi Connection and Strength (Only on MBxL) • Bluetooth (Not used) • Solar input active (Only on SVx) • Mains input active (Only on MBxL) LCD Screen Examples 1. Charging from sunlight (SVx only) 2. Battery Fully Charged 3.
  • Page 18: Installation

    1. Battery Power Source: Attach the energiser to the battery and con- nect the red clip to the positive battery terminal and the black clip to the negative battery terminal. For battery choice see the specification table. Page 18 © JVA Technologies. www.jva-fence.com...
  • Page 19 Mains Power Source: Attach the energiser to the supplied power pack. Plug the power pack into the mains power outlet and turn on the switch at the wall. The mains power pack MUST be kept indoors! Solar Power Source: It is recommended that a solar regulator is used in conjunction with a solar panel and a rechargeable battery.
  • Page 20: Operation

    For best results place the energiser in the middle of long lines of fence. Page 20 © JVA Technologies. www.jva-fence.com...
  • Page 21: Benefits Of Electric Fences

    The fence and the earth voltages can be mea- sured using an electric fence digital voltmeter or digital electric fence directional fault finder (the JVA Electric Fence Fault Finder). BENEFITS OF ELECTRIC FENCES •...
  • Page 22: Electric Fences

    Earth terminal when an animal touches the fence. Earth stake The electrical circuit is closed between the fence and the A good circuit requires adequate current flow through ground when the the ground (through moist soil) animal touches the fence Page 22 © JVA Technologies. www.jva-fence.com...
  • Page 23: Fence Return System

    FENCE RETURN SYSTEM The Fence Return configuration for electric fences is used where the soil could be too dry to complete the circuit, or the animals are likely to try to force their way through between the fence wires. In this system earth wire(s) are also run along the fence with the live wire(s) to provide a low resistance path for the current to return to the energiser.
  • Page 24: Bi-Polar System

    It is also advised not to use any metal water pipes as this could lead to someone receiving a shock from a tap. Page 24 © JVA Technologies. www.jva-fence.com...
  • Page 25: Semi-Permanent And Permanent Fences

    1. Check the fence voltage using an electric fence volt meter. The JVA fault finder will also detect faults and direct you towards them.
  • Page 26: Troubleshooting Energiser Problems

    (See Errors and Error Codes) on the LED and LCD displays. MOISTURE AND ANTS Moisture and Ants should not be a significant problem for the JVA range of energisers as they come in a weatherproof case. Still, where possible, keep the energiser protected from the weather.
  • Page 27: Battery Replacement (Sv5/Sv10 Only)

    BATTERY REPLACEMENT (SV5/SV10 ONLY) The JVA SV series of energisers contain a sealed lead-acid (SLA) or LiFePo4 battery that is charged by the solar panel. If the unit indicates a depleted battery it will flash the red error LED twice. The unit should be turned off and placed in full sun for 2 to 3 days to allow the battery to fully charge.
  • Page 28 (see image below) 5. Remove the battery and replace it with an equivalent 12V SLA battery of the same dimensions (JVA COB004 or AUS. Jaycar SB2486). Remove J1 shunt Alternative battery LiFePO4 (JVA COB010 or AUS. Jaycar SB2210).
  • Page 29: Errors And Error Codes

    ERRORS AND ERROR CODES The JVA energiser may stop and display error codes. The error codes are displayed in two places. The first of these is on the Status (red) LED, where it will flash rapidly a number of times. The number of these flashes cor- responds to the Error Code.
  • Page 30 Should the error continue to re-occur, please return the unit to a qualified service centre for repair. There are no user serviceable parts inside the energiser. All internal fuses will automatically reset themselves. Page 30 © JVA Technologies. www.jva-fence.com...
  • Page 31: Common Fence Problems

    Using an electric fence volt meter or a JVA Electric Fence Fault Finder (do not use a standard multi- meter) check what the voltage is at the earth terminal of the energiser. In general you should see a reading less than 300 volts (0.3kV).
  • Page 32: Definitions

    4. Barbed wire or razor wire shall not be electrified by an energiser. 5. Any part of an electric animal fence that is installed along a public road Page 32 © JVA Technologies. www.jva-fence.com...
  • Page 33 or pathway shall be identified at frequent intervals by warning signs se- curely fastened to the fence posts or firmly clamped to the fence wires. 5.1 The size of the warning sign shall be at least 100 mm x 200 mm. 5.2 The background colour of both sides of the warning sign shall be yel- low.
  • Page 34 • 2 m for power lines operating at a nominal voltage not exceeding 1,000 • 15 m for power lines operating at a nominal voltage exceeding 1,000 V. Page 34 © JVA Technologies. www.jva-fence.com...
  • Page 35: Particular Requirements For Electric Animal Fences In Australia

    PARTICULAR REQUIREMENTS FOR ELECTRIC ANI- MAL FENCES IN AUSTRALIA 1. A distance of at least 10 m shall be maintained between the energiser earth electrode and any other earthing system connected parts such as the power supply system protective earth or the telecommunication system earth.
  • Page 36: Warranty

    Whilst every effort has been made to check that the information contained in this manual is accurate, JVA Technologies will not be liable to loss or damage resulting from construction, operation or failure of any installation or system.
  • Page 37: 10.3 Contacts

    10.3 CONTACTS JVA Australia JVA Technologies PO Box 408 Narangba QLD 4504 Tel: 07 3103 0582 JVA South Africa Bloemfontein Klerksdorp Rustenburg 36 Kolbe Laan, Oranjesig 72 Central Avenue, Flamwood, Shop 7, Waterfall Mall Tel : 051 448 6695/6 Tel : 018 468 8273...
  • Page 38 Notes Page 38 © JVA Technologies. www.jva-fence.com...
  • Page 39 Notes ST035 User Manual Page 39...
  • Page 40 DEALER Manufactured for JVA by Pakton Group The JVA logo is trademark of JVA Technologies Pty Ltd ST035 Cruiser Energiser Manual 1v44 fEncE...

This manual is also suitable for:

Mb12Mb16Sv5Sv10Mb1.5Mb3.0 ... Show all

Table of Contents