Maintenance and Troubleshooting
5-10
Message
What It Indicates
Out of Sync
If Monitor Pattern was
selected, it means the test
pattern generator and
receiver have not yet
synchronized. (Path:
main/test/port- n _ phy or
network_ phy)
If Monitor Pattern was
selected, it means that
5 packets out of 25 are
missing or out of sequence.
(Path: main/test/network,
port-1, port-2, BRI-B1, or
BRI-B2/pvc)
Password Matching
Password entered in the
Error – Re-enter
Re-enter Password field of
Password
the Administer Logins
screen does not match
what was entered in the
Password field.
Set Frame Relay Link
Tried to disable the physical
Status to Disable first
port when the logical link
was up; tried to change
Port Status to Disable while
Link Status was enabled.
Value Out of Range
CIR entered for the DLCI is
a number greater than
64,000, or is a special
character.
Excess Burst Size entered
for the DLCI is a number
greater than 999,999, or is
a special character.
DLCI Number entered is
less than 16 and greater
than 1007.
Warning – Config
Configuration has been
Changed by
loaded and is being saved,
[ SNMP/Autoconfig ]
but the configuration has
been changed via another
mechanism.
If saving the loaded
configuration is completed,
the configuration changes
made via SNMP or
Auto-Configuration
Shortcuts will be lost.
June 1997
What To Do
No action needed.
Verify that the access unit at
the other end is configured to
Send Pattern.
Correct unit configurations.
Check the line's error rate –
the physical line quality.
Contact service provider.
Try again.
Contact your system
administrator to verify your
password.
1. Change Link Status to
Disable.
2. Retry disabling the port.
Enter a valid CIR ( 0 – 64000 ).
Enter a valid Excess Burst Size
( 0 – 999999 ).
Enter a valid number
(16 – 1007 ).
Cancel the Save command;
select No to the Save Changes?
prompt.
9121-A2-GB20-00