Forced Cooling Operation

2. Forced Cooling Operation
Outline
The forced cooling operation is allowed when both the following conditions are met.
1. The outdoor unit is not abnormal and not in the 3-minute standby mode.
2. The outdoor unit is not operating.
Protection functions have priority over all other functions during forced cooling operation.
 With indoor unit ON/OFF switch
Details
Press indoor unit ON/OFF switch (SW1) for at least 5 seconds. The operation will start.
Forced cooling operation will stop automatically after about 15 minutes.
To stop the operation, press indoor unit ON/OFF switch.
94
ON/OFF
switch
DAMA-SM-21-003