Main Functions
1.8

ECO+ Operation

Outline
ECO+ operation reduces the maximum operating power input and adjust the target temperature
setting. This operation is particularly convenient for energy-saving. It is also a major bonus
when breaker capacity does not allow the use of multiple electrical devices and air conditioners.
It can be easily activated by pressing ECO+ button on the wireless remote controller.
Details
User set temperature <
24°C (75°F)
User set temperature ≥
24°C (75°F)
User set temperature >
20°C (68°F)
User set temperature ≤
20°C (68°F)
28
Cool mode
Unit runs at 24˚C (75˚F)
24 (75)
User set
temp
+
ECO
activated
Unit runs at (user set temperature + 1°C (1.8°F)
(User set temp + 1°C (1.8°F)
User
set temp
24 (75)
+
ECO
activated
Heat mode
Unit runs at 20°C (68°F)
User set
temp
20 (68)
+
ECO
activated
Unit runs at (user set temperature - 1°C (1.8°F)
20 (68)
User set
(User set temp - 1°C (1.8°F)
temp
+
ECO
activated
DAMA-SM-21-003