Available languages

  • ENGLISH, page 297
BlueHelix HiTech RRT H
PCB replacement
• Disconnect the power supply and close the gas cock ahead of the valve.
• Undo the two screws "1" and rotate the control panel.
• Raise the electrical box cover by operating on the tabs "2"
• Undo the screws "3". Raise the board by operating on the side tabs "4".
• Remove all the electrical connectors.
• Insert the new board and reconnect the electrical connections.
EN
fig. 51
2
3
3
fig. 52
cod. 3541V481 - Rev. 00 - 06/2021
1
1
2
4
341