Victron energy MultiPlus-II 48V 3kVA 120V Manual page 29

Table of Contents

Advertisement

MultiPlus-II 48V 3kVA 120V
Weight
Dimensions (hxwxd) mm
Safety
Emission, Immunity
1. Can be adjusted to 50 Hz
2. Protection key:
a. output short circuit
b. overload
c. battery voltage too high
d. battery voltage too low
e. temperature too high
f.
120 VAC on inverter output
g. input voltage ripple too high
Page 26
MultiPlus-II 48V 3kVA 120V
536 x 275 x 147 (21 x 11 x 6 inch)
STANDARDS
EN-IEC 60335-1, EN-IEC 60335-2-29
EN-IEC 61000-3-2, EN-IEC 61000-3-3
IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
3. Non-linear load, crest factor 3:1
4. At 75°F / 25°C ambient
5. Programmable relay which can be set for general
alarm, DC under voltage or genset start/stop function.
AC rating: 120V / 4A, DC rating: 4A up to 35VDC and
1A up to 60VDC
6. A. o. to communicate with a Lithium-Ion battery BMS
7. The auxiliary output of an early production batch of
this product was rated at 35A instead of 50A. This
batch has serial numbers starting with HQ2107. Later
batches, with 50A aux. output have serial numbers
starting with HQ2114 or higher.
19 kg (42 lb)
EN 55014-1, EN 55014-2
Technical Specifications

Advertisement

Table of Contents
loading