Domestic Water System Requirements; Plumbing The Domestic Water System - Aqua-Hot 200 Series Installation Manual

Hide thumbs Also See for 200 Series:
Table of Contents

Advertisement

Domestic Water System

Domestic Water System Requirements

Reference A119.2/NFPA 501C Standard on Recreational
Vehicles 1993 Edition for relevant regulatory information
regarding the design of Domestic Water Systems.
The Aqua-Hot is equipped with a pressure relief valve and a
tempering valve in order to provide safe hot water without
chance of scalding or an over-pressurized system.
Plumb the domestic water system according to Figure 28.
NOTE:
Extended exposure to household bleach will corrode the
components of the Aqua-Hot that will potentially dramatically
shorten the operational lifetime of the Aqua-Hot. Under no
circumstances is the Aqua-Hot to be exposed to household bleach
for extended periods of time. This type of damage is not covered by
the Aqua-Hot warranty.
Cold Water Faucets
Demand Pump
Fresh Water
Storage Tank
p. 18
©Aqua-Hot®
250 Propane Installation Manual

Plumbing the Domestic Water System

The Aqua-Hot is also able to provide domestic hot water
while the boiler tank is up at operating temperature. Activate the
propane burner to provide adequate heat for hot water needs.
The electric element will only provide light duty hot water.
The tempering valve is integrated into the cabinet of the
Aqua-Hot, and is set upon departure from the Aqua-Hot factory.
So long as the tempering valve is not modifi ed, it will provide
hot, non-scalding water.
Instructions
1. Locate the domestic cold water inlet (blue PEX tube) and
connect it to the vehicle's domestic cold water system.
2. Locate the domestic hot water outlet (red PEX tube) and
connect it to the vehicle's domestic hot water system.
To Hot Water
Faucets
Tempered
Domestic Hot Water
Figure 28