TABLE OF THE DIFFERENT STATES OF THE DISPLAY
Display
Meaning
Standby
St-by
FLO
No/insufficient water flow
AL10 / AL11
HP error
AL15 / AL16
Excessive temperature difference
between water outlet/inlet
AL18
Excessive temperature at the com-
pressor outlet
AL17
Temperature protection too low in
cooling mode
AL7 / AL8
Communication error.
Sensor error (water inlet)
AL3
Sensor error (water outlet)
AL4
Sensor error (evaporator)
AL5
Sensor error (compressor outlet)
AL1
Sensor error (compressor inlet)
AL2
AL6
Sensor error (ambient)
AL9
Fan error
AL14
Temperature too low
AL19 / AL20
Power supply issue
AL21 / AL22
AL23 / AL24
Electronic/overheating problem.
AL25
Remote controlling by connection to the RS-485
Your HP can be controlled through a dry contact (switch) or the Pentair RS-485 bus.
1: Open the top hood by unscrewing
2: Open the top of the connec-
the 6 screws:
tion box by unscrewing the 4
screws:
Dry contact inlet (remote ON-OFF), remove the shunt that is present
Connection to Maestro:
N
L
N
ON ?
AUX1 CL
230 V ~
230 V ~
230 V ~ 10A 230 V ~ 10A 230 V ~ 10A 230 V ~ 10A 230 V ~ 10A
230 V ~
BUS
10
Verification
Action required
–Check the water flow in the device.
–Check the clogging of the filter.
–Check the bypass setting.
–Check the direction of the passage of water
in the device (inlet bottom, outlet top).
Check the connections between the display
Contact your distributor.
and the electronic card in the device.
Check that the sensor in question is correct-
ly connected.
Check the fan connections.
Wait for the temperature to
The outdoor temperature is < 0°C.
rise.
Have the installation checked by a qualified
technician.
Power down the device for 5 to 10 minutes,
Contact your distributor.
check that it is properly ventilated, and that
the air flow is not blocked or slowed down.
Power the device back up.
3: Connect either the switch (IN in
4: Pull a suitably-sized cable through the
ON-OFF) or the RS-485.
free cable-gland.
BUS
BUS
BUS
IN
IN
YEL
GRN
GND
GND
5: Pull the cable through the side hole, follow
the cable path to the terminal strip.
ON / OFF
RS-485
Couleur
Indicative
indicative
colour
Pentair connection bus (IntelliPool, Speedeo ...)
Connection to Speedeo:
Connection to IntelliPool:
pH
CL
L
BUS
BUS
MAINTENANCE
– Prior to undertaking any maintenance operation on the HP, it is imperative to disconnect the power supply from the HP: there is a risk of electrocution that
can cause damages, severe injuries, and even death. Maintenance operations are to be conducted by a qualified technician.
Cleaning (must be conducted by a qualified technician at least once yearly):
– The cleaning of the inlet of the evaporators and of the outlet of the fan are necessary to maintain a sufficient yield.
– The HP outer casing must be cleaned with a damp soft cloth (microfibre for example). The use of detergent and other household products might damage the
surface of the casing and change its properties.
– The evaporator, at the rear of the HP, can be cleaned carefully using a soft brush vacuum cleaner, just a soft brush, or a stream of soft water; never use a
high-pressure hose.
Yearly maintenance, safety checks (must be conducted by a qualified technician at least once yearly):
Prior to any maintenance operation, it is imperative to power down the device and to wait a few minutes before installing pressure control devices, as the
high pressure and temperature in some parts of the cooling circuit could cause severe burns.
– Check that the electric cables are properly connected.
– Check that the earth terminals are properly connected to the earth.
– Check the state of the pressure gauge, and that the pressure is aligned with the temperature (table below), and for the presence of coolant.
+60°C = 38.3 bar
+32°C = 19.3 bar
+20°C = 13.7 bar
+55°C = 34.2 bar
+30°C = 18.3 bar
+18°C = 12.9 bar
+50°C = 30.4 bar
+28°C = 17.3 bar
+16°C = 12.2 bar
+45°C = 26.9 bar
+26°C = 16.3 bar
+14°C = 11.4 bar
+40°C = 23.8 bar
+24°C = 15.4 bar
+12°C = 10.7 bar
+35°C = 20.9 bar
+22°C = 14.5 bar
+10°C = 10.0 bar
1 - Turn off the power supply to the HP
2 - Fully open the bypass valve and close the HP inlet and outlet valves.
Open valve
3 - Unscrew the junctions to evacuate all the
4 - Reconnect and slightly tighten the junctions
water contained in the HP.
+8°C = 9.4 bar
-4°C = 6.1 bar
-16°C = 3.7 bar
+6°C = 8.8 bar
-6°C = 5.7 bar
-18°C = 3.3 bar
+4°C = 8.2 bar
-8°C = 5.2 bar
-20°C = 3.0 bar
+2°C = 7.6 bar
-10°C = 4.8 bar
0°C = 7.1 bar
-12°C = 4.4 bar
-2°C = 6.6 bar
-14°C = 4.0 bar
pH +/-
Half-open valve
Closed valve
5 - Place the provided wintering blanket
by hand to prevent the introduction of foreign
over the HP
objects into the HP