Environmental Specifications; Table 1-4: Environmental Specifications - Aerotech ACS100 Hardware Manual

Table of Contents

Advertisement

1.1. Environmental Specifications

1.1. Environmental Specifications
W A R N I N G :  Do not expose this product to environments or conditions outside of the listed
specifications. Exceeding environmental or operating specifications can cause damage to the
equipment.
Table 1-4:
Environmental Specifications
Ambient
Temperature
Humidity
Altitude
Vibration
Protection
Rating
Use
12
Operating: 10° to 35° C (50° to 95° F)
The optimal operating temperature is 20° C ±2° C (68° F ±4° F). If at any time the
operating temperature deviates from 20° C, degradation in performance could occur.
Storage: 0° to 40° C (32° to 104° F) in original shipping packaging
Operating: 20% to 60% RH
Storage: 10% to 70% RH, non-condensing in original packaging. The stage should be
packaged with desiccant if it is to be stored for an extended time.
Operating: 0 m to 2,000 m (0 ft to 6,562 ft) above sea level
Contact Aerotech if your specific application involves use above 2,000 m or below sea
level.
Use the system in a low vibration environment. Excessive floor or acoustical vibration
can affect system performance. Contact Aerotech for information regarding your spe-
cific application.
The ACS stages are not suited for dusty or wet environments. This equates to an
ingress protection rating of IP40.
Indoor use only
ACS Hardware Manual
www.aerotech.com