Accessories; Possible Failures And Cure - Lincar Monella 940 Using Instructions And Maintenance

Residential space heating appliances with boiler fired by wood pellets
Table of Contents

Advertisement

Available languages

Available languages

Accessories

The following accessories are supplied with the appliance :
For warm parts
To clean the fume ducts (Attention, this tool is placed into the
accessories bag, we remind that at the inside part of the lower
door there is a special support where you can store it).
Possible troubles and their cure
TROUBLE
The presetted room
temperature is not
obtained
The appliance is
working at
minimum power.
The fuel is
accumulating itself
into the burner
basket.
The heating plant
(thermo siphon) is
tepid
Any repairs must be carried out by an authorized after-sales service or
qualified staff.
Attention: Disconnect always the appliance before making any intervention.
CORISIT S.r.l. is not responsible for damages to thing or people due to a wrong installation,
equipment tampering, improper use, bad maintenance or no observation of normative in
force. If considerate appropriate, CORISIT S.r.l. reserves the right to make modifications
without notice and in every moment.
Some particulars and accessories illustrated in this handbook are not mass produced item so
its extra costs are to check at contract release.
CAUSE
Appliances power set to low
Boiler temperature set to low
Loss of heat.
The heating plant is too big, compared
to the power of the appliance.
The room temperature has reached the
requested value.
The boiler has reached the set
temperature.
The heating plant is too small,
compared to the power of the
appliance.
Fuel of low quality.
Carburation/maintenance of appliance
Ashtray cover opened or not correctly
closed.
Appliance just started.
The room temperature has reached the
requested value.
The boiler temperature has reached
the set value.
CURE
Increase the power.
Increase the boiler temperature
Improve the plant and house
insulations.
Reduce the dimension of the plant.
Set up a higher temperatur.
Set up a higher boiler temperatur.
Increase the dimension of the plant.
Improve the quality of the fuel.
Effect Cleaning by User and/or
ordinary maintenance. Effect a pellet
correction (menu09).
Verify if the ashtray cover is correctly
closed.
Wait until the appliance has reached
the normal working range.
Set up a higher room temperature.
Set up a higher boiler temperature.
68/112
IT-GB-FR mod. 940-940/SA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Monella 940/sa050809050000

Table of Contents