Charging Curves - NDS POWERSERVICE PLUS 25 User Manual

Hide thumbs Also See for POWERSERVICE PLUS 25:
Table of Contents

Advertisement

6. charging curves

powerservice
flooded lead-acid batteries or Vmax 14.5V, a special curve for
Euro 6 systems with "smart" alternators and LiFePO4 lithium
batteries . The charge curves are selectable using two jumpers.
a curve: AGM
yes
no
b curve: gel
yes
yes
units support battery charging for AGM, Gel and
Model
max voltage
float voltage
max desulfation voltage
Model
max voltage
float voltage
max desulfation voltage
11
12V
24V
14,8V
29,6V
13,8V
27,6V
15,8V
31,6V
12V
24V
14,3V
28,6V
13,6V
27,2V
15,8V
31,6V