3. Connect the fuse holder to the positive pole of the STARTer
BATTERY.
4. Connect the other end of the fuse holder to Pin N°3 of the
powerservice.
5. Insert a 70A fuse into the fuse holder.
6. Connect the negative terminal of the service battery to Pin
No. 2 of the powerservice.
7. Disconnect all the cables on the positive pole of the service
battery and connect them to pin N°5 of the
(Not valid for models plus 12-24 and gold 12-24)
8. Connect the service battery positive pole to Pin N°6 of the
powerservice
9. connect the D+ OR IGNITION+ SIGNAL WIRE to the
Pin n°4.
10. only for Gold models: connect the 230VAc mains supply to the
input iec connector. link the connection after the general
system safety switch (rcd switch).
to avoid interferences in audio / video systems:
use high quality (and in good condition) cables for TV
antennas and other transceivers.
make sure that the powerservice's power cables (input and
output) are far from transceivers cables, sensitive devices
power cables and ac current cables.
Place sensitive equipment as far as possible from the
powerservice.
NOTe
the data connector placed on the right of the power
connector is for technical use. it is strictly forbidden to
connect any device in this socket, any tampering could
irreparably damage the appliance.
use cables with a cross-section of at least 10
connections between engine battery and Power Service, and
in the output towards the service battery. if the distance
between the motor battery and the device exceeds 2 meters,
it's RECOMMENDED to increase the cable section, to reduce
voltage drop and power losses.
17
powerservice
powerservice
for:
mm
2

Hide quick links:

Advertisement

Table of Contents
loading