Summary of Contents for SHOWTEC Spectral M800 Q4 IP
Page 1
USER MANUAL ENGLISH Spectral M800 Q4 IP Product code: 43571 Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
Page 2
Spectral M800 Q4 IP Preface Thank you for purchasing this Showtec product. The purpose of this user manual is to provide instructions for the correct and safe use of this product. Keep the user manual for future reference as it is an integral part of the product. The user manual shall be stored at an easily accessible location.
Spectral M800 Q4 IP Table of contents Introduction ................................4 Before Using the Product ..........................4 Intended Use ............................... 4 Product Lifespan ..............................4 LEDs Lifespan ............................... 4 Text Conventions ..............................4 Symbols and Signal Words ..........................5 Symbols on the Information Label ........................5 Safety ..................................
After unpacking, check the contents of the box. If any parts are missing or damaged, contact your Highlite International dealer. Your shipment includes: ● Showtec Spectral M800 Q4 IP ● Schuko to Seetronic power cable (1,5 m) ● Safety cable ●...
Spectral M800 Q4 IP ● References: References to chapters and parts of the device are in bold lettering, for example: “Refer to 2. Safety”, “turn the adjustment screw (02)” ● 0–255: Defines a range of values ● Notes: Note: (in bold lettering) is followed by useful information or tips Symbols and Signal Words Safety notes and warnings are indicated throughout the user manual by safety signs.
Spectral M800 Q4 IP Safety Important Read and follow the instructions in this user manual before installing, operating or servicing this product. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual. Warnings and Safety Instructions...
Page 8
Spectral M800 Q4 IP ● Make sure that the cable run is not too heavy. A heavy cable run can cause damage to the connectors. If the connectors are damaged, their ingress protection (IP) can deteriorate. WARNING Risk of burns due to hot surface The surface and the inner parts of the device can become very hot during operation.
Spectral M800 Q4 IP ● If the device is dropped or struck, disconnect the device from the electrical power supply immediately. ● If the device is exposed to extreme temperature variations (e.g. after transportation), do not switch it on immediately. Let the device reach room temperature before switching it on, otherwise it may be damaged by the formed condensation.
Spectral M800 Q4 IP Description of the Device The Spectral M800 Q4 IP is a LED fixture with high output and great effects. Front View Fig. 02 01) 14 x 5 W RGBW LED 02) Mounting bracket 03) Adjustment screw...
Spectral M800 Q4 IP Back View Fig. 03 04) IP65-rated Seetronic 3-pin DMX signal connector IN 05) IP65-rated Seetronic power connector IN 06) Safety eye 07) IP65-rated Seetronic power connector OUT 08) IP65-rated Seetronic 3-pin DMX signal connector OUT 09) 4-digit LED display + menu buttons...
Spectral M800 Q4 IP Product Specifications Model: Spectral M800 Q4 IP Electrical: Input voltage: 100–240 V AC, 50/60 Hz Power consumption: 65 W Physical: Dimensions: 180 x 235 x 323 mm (LxWxH) Weight: 4,3 kg Optics: Light source: 14 x 5 W RGBW LED Dimmer: 0–100 %...
Spectral M800 Q4 IP Optional Accessories The Spectral M800 Q4 IP is delivered without accessories. You can additionally purchase the following accessories: Product code: 43514 (Showtec Accessory Frame for Spectral) Product code: 43520 (Showtec Barndoor Quanta 3500/Spectral) Product code: 43521...
Spectral M800 Q4 IP Installation Safety Instructions for Installation WARNING Incorrect installation can cause serious injuries and damage of property. If trussing systems are used, installation must be carried out only by instructed or skilled persons. Follow all applicable European, national and local safety regulations concerning rigging and trussing.
Spectral M800 Q4 IP Rigging The device can be positioned on a flat surface or mounted to a truss or other rigging structure in any orientation. Make sure that all loads are within the pre-determined limits of the supporting structure.
Spectral M800 Q4 IP Angle Adjustment You can adjust the angle of the device with the adjustment screw (03). 03) Turn the adjustment screw (03) counterclockwise to release it. 04) Tilt the device to the desired angle (see Fig. 06).
Spectral M800 Q4 IP Accessory Frame Installation In order to be able to install the optional accessories, you need to install the accessory frame first. It is equipped with a spring-loaded retaining clip which prevents the accessories from falling out.
Spectral M800 Q4 IP Barndoor Installation The accessory frame is equipped with a spring-loaded retaining clip. This prevents the barndoor from falling out. Install the accessory frame. See 4.4.2. Accessory Frame Installation on page 16 for more information. Press on the retaining clip on the accessory frame to open it.
Spectral M800 Q4 IP Tophat Installation The accessory frame is equipped with a spring-loaded retaining clip. This prevents the tophat from falling out. Install the accessory frame. See 4.4.2. Accessory Frame Installation on page 16 for more information. Press on the retaining clip on the accessory frame to open it.
Spectral M800 Q4 IP Filter Frame Installation The accessory frame is equipped with a spring-loaded retaining clip. This prevents the filter frame from falling out. Install the accessory frame. See 4.4.2. Accessory Frame Installation on page 16 for more information.
Spectral M800 Q4 IP Free-standing Bracket Installation Put the free-standing bracket on the Spectral. Install all elements as shown in Fig. 11. Tighten the screws. Fig. 11 Product code: 43571...
Spectral M800 Q4 IP Connecting to Power Supply DANGER Electric shock caused by short-circuit The device accepts AC mains power at 100–240 V and 50/60 Hz. Do not supply power at any other voltage or frequency to the device. This device falls under IEC protection class I. Make sure that the device is always electrically connected to the ground (earth).
Disconnect power supply before connecting or disconnecting data cables. Stand-alone Setup When the Spectral M800 Q4 IP is not connected to a controller or to other devices, it functions as a stand- alone device. It can be operated manually or in auto mode.
Fig. 12. Fig. 12 Master/Slave Setup The Spectral M800 Q4 IP supports master/slave control mode. To connect multiple devices in master/slave setup, follow the steps below: 01) Connect the first device’s DMX OUT connector to the second device’s DMX IN connector.
04) Continue assigning the starting addresses of the remaining devices by adding each time 15 to the previous number. Make sure that you do not have any overlapping channels in order to control each Spectral M800 Q4 IP correctly. If two or more devices are addressed similarly, they will work similarly.
Before connecting the device to the power supply, make sure that the current, voltage and frequency match the input voltage, current and frequency specified on the information label on the device. Control Modes The Spectral M800 Q4 IP supports the following control modes: ● Stand-alone: Static Colors, Built-in programs ●...
Spectral M800 Q4 IP To operate the device with a DMX controller: 01) Select DMX mode in the submenu. See 6.6.3. Master/Slave Mode on page 30 for more information. 02) Set the DMX starting address of the device in the DMX Address submenu. See 5.3. DMX Connection on page 22 and 6.6.4.
Spectral M800 Q4 IP Main Menu Options The main menu has the following options: Static colors Built-in and custom programs Master/Slave mode DMX address DMX configuration Edit mode Settings Calibration Safety lock Info 01) Press the UP/DOWN buttons to navigate through the main menu.
Spectral M800 Q4 IP Built-in and Custom Programs In this menu you can set the built-in programs or choose your edited custom programs. 01) Press the UP/DOWN buttons until the display shows 02) Press the ENTER button to open the menu.
Spectral M800 Q4 IP Edit Mode In this menu you can create your own custom shows. 01) Press the UP/DOWN buttons until the display shows 02) Press the ENTER button to open the menu. 03) Press the UP/DOWN buttons to choose the desired custom program: PR.01–10. Each custom program has 30 scenes, which can be edited.
Spectral M800 Q4 IP Reset In this menu you can reset the custom programs. 01) Press the UP/DOWN buttons until the display shows 02) Press the ENTER button to open the menu. 03) Insert the password: UP>DOWN>UP>DOWN and press the ENTER button to confirm. The display will show and the custom programs will be reset.
Spectral M800 Q4 IP Dimming Curves In this submenu you can set the dimming curves. 01) Press the UP/DOWN buttons until the display shows 02) Press the ENTER button to open the menu. 03) Press the UP/DOWN buttons to choose one of the 4 dimming curves: ●...
Spectral M800 Q4 IP Strobe Settings In this menu you can choose the desired strobe mode. 01) Press the UP/DOWN buttons until the display shows 02) Press the ENTER button to open the menu. 03) Press the UP/DOWN buttons to toggle between the following 2 options:...
Spectral M800 Q4 IP RGB Calibration In this menu you can adjust the temperature of the white color. 01) If the display shows , press the ENTER button to open the menu. The display shows 02) Press the ENTER button to open the submenu.
Spectral M800 Q4 IP DMX Channels RGB Personalities AR1.D TOUR TR16 Function Value Setting (4 Ch) (9 Ch) (13 Ch) Master Dimmer 000–255 From low to high intensity (0–100 %) Dimmer Fine 000–255 From low to high intensity (0–100 %) 000–255...
Spectral M800 Q4 IP RGBW Personalities ARC.2 AR2.D AR2.S Function Value Setting (4 Ch) (5 Ch) (6 Ch) Master Dimmer 000–255 From low to high intensity (0–100 %) 000–255 From low to high intensity (0–100 %) Green 000–255 From low to high intensity (0–100 %) Blue 000–255...
Page 40
Spectral M800 Q4 IP 8BIT 16BI Function Value Setting (7 Ch) (10 Ch) (15 Ch) 010–255 From low to high frequency (0–20 Hz) 000–020 No function 021–030 AUTO01 031–040 AUTO02 041–050 AUTO03 051–060 AUTO04 061–070 AUTO05 071–080 AUTO06 081–090 AUTO07 091–100...
Spectral M800 Q4 IP Troubleshooting This troubleshooting guide contains solutions to problems which can be carried out by an ordinary person. The device does not contain user-serviceable parts. Unauthorized modifications to the device will render the warranty void. Such modifications may result in injuries and material damage.
Spectral M800 Q4 IP Maintenance Safety Instructions for Maintenance DANGER Electric shock caused by dangerous voltage inside Disconnect power supply before servicing or cleaning. WARNING Risk of burns due to hot surface Allow the device to cool down for at least 15 minutes before servicing or cleaning.
Spectral M800 Q4 IP Basic Cleaning Instructions The external lens of the device must be cleaned periodically in order to optimize the light output. The cleaning schedule depends on the conditions at the site where the device is installed. When smoke or fog machines are used at the site, the device will need more frequent cleaning.
Spectral M800 Q4 IP Deinstallation, Transportation and Storage Instructions for Deinstallation WARNING Incorrect deinstallation can cause serious injuries and damage of property. ● Let the device cool down before dismounting. ● Disconnect power supply before deinstallation. ● Always observe the national and site-specific regulations during deinstallation and derigging of the device.
Page 46