Pilot burner,
1. Remove the knobs and control
thermocouple,
panel;
igniter assem-
2. Remove the cast-iron oven plate
bly Oven
and the pilot assembly protection;
3. Replace the component;
For installation carry out the same
procedure in reverse order.
Oven main
1. Remove the cast-iron oven plate;
burner
2. Remove the burner protection
plate;
3. Remove the burner and replace it.
For installation carry out the same
procedure in reverse order.
G.4

Maintenance intervals

All the components requiring maintenance are accessible from the front or the rear panel of the appliance.
The inspection and maintenance intervals depend on the actual machine operation conditions and ambient conditions (presence of
dust, damp, etc.), therefore precise time intervals cannot be given.
In any case, careful and periodical machine maintenance is advisable in order to minimise service interruptions.
To ensure constant machine efficiency, it is advisable to carry out the checks with the frequency given in the following table:
IMPORTANT
Machine maintenance, checking and overhaul operations must only be carried out by a specialised Technician or the
Customer Care Service, provided with adequate personal protection equipment (safety shoes and gloves), tools and
ancillary means;
Work on the electrical equipment must only be carried out by a specialised electrician or the Customer Care Service.
Maintenance, inspections, checks and cleaning
Ordinary cleaning
• general cleaning of machine and surrounding area.
Mechanical protection devices
• check their condition and for any deformation, loosening or
removed parts.
Control
• check the mechanical part, for cracks or deformation, tighten-
ing of screws: check the readability and condition of words,
stickers and symbols and restore if necessary.
Machine structure
• tightening of main bolts (screws, fixing systems, etc.) of
machine.
Safety signs
• check the readability and condition of safety signs.
Electrical control panel
• check the electrical components installed inside the electrical
control panel. Check the wiring between the electrical panel
and machine parts.
Electrical connection cable and plug
• check the connection cable (replace if necessary) and plug.
Preventive maintenance
• check all gas components (if present).
Preventive maintenance
• remove any deposits of dirt inside the appliance.
Control
• check the conditions of the internal parts.
Control
• check and clean the discharge system.
General machine overhaul
• check all components, electrical equipment, corrosion, pipes...
1.
In particular conditions (e. g. intensive use of the appliance, salty environment, etc.) the preventive maintenance should be more frequent.
2.
the machine is designed and built for a duration of about 10 years. After this period of time (from commissioning) the machine must undergo a general
inspection and overhaul. Some examples of checks to be carried out are given below.
22
Abnormal operation
Any of the following are considered to be abnormal
operation and may require servicing:
• incomplete ignition of the burner;
• yellow tipping of the burner flame;
• burner failing to remain alight;
• gas valves are difficult to turn;
In case the appliance fails to operate correctly, contact
the authorised service provider in your area.
G.3

Repair and extraordinary maintenance

NOTE!
Repair and extraordinary maintenance have to be
carried out by specialised authorised personnel,
who can ask the manufacturer to supply a service
manual.
Frequency
Daily
Yearly
Yearly
Yearly
Yearly
Yearly
Yearly
Yearly
1
Every 6 months
1
Every 6 months
1
Every 6 months
2
Every 10 years
Responsibility
Operator
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service
Service