Smoke Control Areas and you can contact them for details of Clean Air Act requirements. The HWAM 4100 and 4200 stoves detailed below have been recommended as suitable for use in smoke control areas when burning wood logs.
™ marT onTrol Congratulations on your new wood-burning stove complete with a HWAM Autopilot IHS We are pleased that you have chosen a HWAM woodburning stove and confident that it will give you much pleasure. The HWAM SmartControl is a digital control of the combustion in your new wood-burning stove. The ®...
In general To ensure optimum operation and safety, we recommend that the installation should be carried out by an authorised HWAM retailer or a fitter recommended by the retailer. For an overview of HWAM retailers, visit www.hwam.com under “Retailer locations”.
Page 11
European, national and local regulations must be observed in terms of the size and thickness of a non- combustible floor covering the floor in front of the combustion chamber opening. Ask your HWAM retailer for assistance. The combustion chamber opening is 28.4 cm wide.
Page 12
The chimney and flue duct must be of flue class T400 and be CE marked. Furthermore, it must have obtained the classification of G in soot fire testing. The required distance to combustible material must be complied with in accordance with the brand label. Ask your HWAM retailer for further information.
If the chimney is too tall to be cleaned from above, it must be equipped with a soot door. In case of a chimney fire and overheating, the HWAM SmartControl will enter a security mode and ®...
Page 14
hazardous and harmful to the environment. These substances could also damage your wood burning stove and chimney, rendering the product warranty void. Storage of wood A moisture content of 12-18% is achieved by storing recently felled wood outdoors under a lean-to for at least one year, preferably 2 years.
Page 15
The HWAM SmartControl ® ® will signal that a restoking is due at the flue gas temperature of 180° C, and at 100° C the HWAM ® SmartControl will enter standby mode and all dampers will close.
• If the room temperature after a new restoking still does not reach the desired level, the water content in the firewood may be too high or the draught in the chimney too weak. The HWAM SmartControl ®...
® combustion. A good combustion is achieved when the fire gets the right amount of oxygen supply at the right time and place in the combustion chamber. The HWAM SmartControl allows for variations ®...
In case the safety alarms go off, you must not use the stove. Contact your retailer as soon as possible. At interruptions that you cannot yourself rectify, you should contact the retailer. eClaraTion oF erFormanCe The DoP can be downloaded from our website via the following links: www.hwam.com/dop/4100ihs www.hwam.com/dop/4200ihs Page 18 of 20 pages...
Product information on solid fuel local space heaters according to Comission regulation (EU) 2015/1185 HWAM 4110 IHS, HWAM 4120 IHS, HWAM 4130 IHS, Model HWAM 4140 IHS, HWAM 4150 IHS, HWAM 4160 IHS, HWAM 4240 IHS Direct heat output [kW]...
Need help?
Do you have a question about the 4110 and is the answer not in the manual?
Questions and answers