Summary of Contents for S+S Regeltechnik PREMASGARD 232 wModbus Series
Page 1
Руководство по монтажу и обслуживанию Преобразователь давления измерительный и преобразователь давления измерительный дифференциальный, вкл. комплект соединительных деталей, с модулем W-Modbus (Wireless) S+S REGELTECHNIK GMBH THURN-UND-TAXIS - STR. 22 90411 NÜRNBERG ⁄ GERMANY CARTONS FON +49 ( 0 ) 911 ⁄ 5 19 47- 0 ET EMBALLAGE mail@SplusS.de...
Page 2
D G U F r 232x - wModbus PREMASGARD ® Maßzeichnung Dimensional drawing Plan coté Габаритный чертеж mit Display [mm] with display avec écran M20x1.5 с дисплеем M20x1.5 M20x1.5 ohne Display without display sin écran без дисплея M20x1.5 M20x1.5 M20x1.5 M12-Steckverbinder (optional auf Anfrage) M12 connector...
® PREMASGARD 232x - wModbus Rev. Data - V43 Wartungsfreier Druckfühler PREMASGARD ® 232x - wModbus (Serie) mit W-Modbus (Wireless), im schlagfesten Kunststoff gehäuse mit Schnellver- schlussschrauben, Anschluss-Stutzen für Druckschlauch (Ø 6 mm), mit Kabel ver schraubung (optional M12-Steckverbinder nach DIN EN 61076-2-101), wahl weise mit ⁄...
Page 4
® PREMASGARD 232x - wModbus Rev. Data - V43 ® Montageschema PREMASGARD ÜBERWACHUNGSARTEN 232x - wModbus Unterdruck P1 (+) wird nicht angeschlossen, ist luftseitig offen gegen Atmosphäre P2 (–) Anschluss im Kanal Filter: P1 (+) Anschluss vor dem Filter P2 (–) Anschluss nach dem Filter Ventilator P1 (+) Anschluss nach dem Ventilator P2 (–) Anschluss vor dem Ventilator...
W-Modbus (Wireless) | Inbetriebnahme (Slave) W-Modbus-Sensor (Slave) STATUS-LEDS Die beiden LEDs L1 und L2 (rechts neben dem Pair-Taster) zeigen den Funkstatus des Sensors an. Diese sind nach dem Einschalten aktiv und werden nach ca. 30 Minuten automatisch deaktiviert. Bei Bedarf können die LEDs mittels Pair-Taster manuell reaktivert werden. TELEGRAMM-LED Die LED (links neben dem DIP-Schalter A) zeigt durch Blinken eine aktive Modbus-Kommunikation an.
Page 7
W-Modbus-Sensor (Slave) ANLERNEN (PAIRING) "Slave" Werkseitig steht die Busadresse auf „1“ und kann über DIP-Schalter umgestellt werden (siehe Abschnitt „Modbus-Konfiguration“). Das Ändern der Busadresse ist jederzeit möglich, auch nach dem Koppeln an ein Gateway. Zum Anlernen eines W-Modbus-Sensors (Slave) an ein Master-Gateway (DDC/SPS), müssen beide Geräte in den Pairing-Modus (Anlernmodus) gesetzt werden.
Page 8
W-Modbus (Wireless) | Netzwerk-Installation Allgemeiner Aufbau Bustopologie mit Abschluss- und Vorspannungswiderständen (Mischform) MODBUS RTU-Master Pull-Up- / Vorspannungswiderstand BIAS A (D1) D+ Leitungs- abschluss B (D0) D– Pull-Down- / Vorspannungswiderstand BIAS Common (GND) MODBUS MODBUS W-MODBUS Slave Slave Gateway W-MODBUS Slave 1 W-MODBUS W-MODBUS MODBUS...
Page 9
PREMASGARD ® 232x - wModbus | Konfiguration BUSADRESSE Werkseitig steht die Busadresse auf „1“ und kann über DIP-Schalter umgestellt werden. Das Ändern der Busadresse ist jederzeit möglich, auch nach dem Koppeln an ein Gateway. Bei Displaygeräten wird die geänderte Busadresse für ca. 30 Sekunden im Display angezeigt. Konfiguration am Beispiel "193"...
PREMASGARD ® 232x - wModbus | Konfiguration ANZEIGE IM DISPL AY Der Anzeigewert ist abhängig vom eingestellten Einheitensystem (siehe Tabelle „Function 05 Write Single Coil“). Bei Bedarf kann das Geräte von SI (default) auf Imperiale Einheiten umgestellt werden. Standardanzeige Standardmäßig wird in der ersten Zeile der Wert und in der zweiten Zeile die entsprechende Einheit statisch angezeigt: Differenzdruck [Pa] [inWC] Frei konfigurierbare Anzeige Über die Modbusschnittstelle kann die Display-Anzeige sowohl im 7-Segment-Bereich als auch im Dot-Matrix-Bereich...
Page 11
PREMASGARD ® 232x - wModbus | Konfiguration, Telegramme ASCII-Code-Tabelle für Dot Matrix Anzeigebereich ASCII Sign ASCII Sign ASCII Sign ASCII Sign ASCII Sign Leer “ & < > ü ä Ä ö Ö Ü ° Nicht in der Tabelle aufgeführte ASCII-Zeichen bzw. Steuerzeichen werden als Leerzeichen dargestellt. TELEGRAMME Function 04 Read Input Register Register...
PREMASGARD ® 232x - wModbus | Telegramme Function 05 Write Single Coil Register Parameter Data Type Value Range Autozero (Differenzdruck) 0x0001 Bit 0 0 / 1 OFF - ON 0x0002 Einheitensystem → Imperial Bit 1 0 / 1 SI (Default) - Imperial Differenzdruck [Pa]...
Page 13
PREMASGARD ® 232x - wModbus | Telegramme Function 08 Diagnostics Folgende Sub Function Codes werden unterstützt Sub Function Parameter Data Type Antwort Code Echo der Sendedaten Echodaten (Loopback) Neustart Modbus Echo Telegramm (Reset Listen Only Mode) Aktivierung Listen Only Mode Keine Antwort Lösche Zähler Echo Telegramm...
Wichtige Hinweise Hiermit erklärt S+S Regeltechnik GmbH, dass der Funkanlagentyp 232x-wModbus der Richtlinie 2014/53/EU entspricht. Der vollständige Text der EU-Konformitätserklärung ist unter folgenden Internetadresse verfügbar: www.spluss.de/130112CF0910200/ Die Einbaulage ist beliebig. Die Druckbereiche (Messbereiche) sind auf dem Geräteetikett angeben. Bei Messdrücken außerhalb dieses Bereiches kommt es zu Fehlmessungen, zu erhöhten Abweichungen oder es kann zur Zerstörung des Druckmessumformer führen.
® PREMASGARD 232x - wModbus Rev. Data - V43 Maintenance-free pressure sensor PREMASGARD ® 232x - wModbus (series) with W-Modbus (wireless), in an impact-resistant plastic housing with quick-locking screws, connection nozzles for pressure hose (Ø 6 mm / 0.24 in), with cable gland (optionally M12 connector according to DIN EN 61076-2-101), optionally with/without display, for measuring the differential pressure (max.
Page 16
® PREMASGARD 232x - wModbus Rev. Data - V43 ® Mounting diagram PREMASGARD TYPES OF MONITORING 232x - wModbus (A) Below-atmospheric pressure P1 (+) is not connected but open against atmosphere P2 ( – ) connected to inside of duct (B) Filter P1 (+) connected upstream of filter P2 ( –...
Page 18
W-Modbus (wireless) | Commissioning (Slave) W-Modbus sensor (slave) STATUS LEDS The two LEDs L1 and L2 (on the right of the "Pair" push-button) indicate the wireless state of the sensor. They activate after the system is switched on and deactivate automatically after approx. 30 minutes. If required, the LEDs can be reactivated manually using the "Pair"...
Page 19
W-Modbus sensor (slave) PAIRING "Slave" The bus address is set to "1" at the factory and can be changed using DIP switches (see "Modbus configuration" section). The bus address can be changed at any time, even after pairing to a gateway. To pair a W-Modbus sensor (slave) to a master gateway (DDC/PLC), both units must be set to Pairing mode.
Page 20
W-Modbus (wireless) | Network installation General bus topology structure with terminating and bias resistors (Mixed configuration) MODBUS RTU-Master Pull-up / bias resistor BIAS A (D1) D+ Line termination B (D0) D– Pull-down / bias resistor BIAS Common (GND) MODBUS MODBUS W-MODBUS Slave Slave...
PREMASGARD ® 232x - wModbus | Configuration BUS ADDRESS The bus address is set to "1" at the factory and can be changed using DIP switches. The bus address can be changed at any time, even after pairing to a gateway. With display units, the modified bus address is shown on the display for approx.
Page 22
PREMASGARD ® 232x - wModbus | Configuration READOUT IN THE DISPL AY The display value depends on the set unit system (see table “Function 05 Write Single Coil”). If required, the unit can be switched from SI (default) to imperial units. Standard display By default, the first line indicates the value while the second line indicates the corresponding unit statically: differential pressure [Pa] [inWC]...
Page 23
PREMASGARD ® 232x - wModbus | Configuration, Telegrams ASCII Code Table for Dot Matrix Display Area ASCII Sign ASCII Sign ASCII Sign ASCII Sign ASCII Sign Blank “ & < > ü ä Ä ö Ö Ü ° ASCII characters or control characters are displayed as spaces. TELEGRAMS Function 04 Read Input Register Register...
Page 24
PREMASGARD ® 232x - wModbus | Telegramms Function 05 Write Single Coil Register Parameters Data Type Value Range Auto zero (Differential pressure) 0x0001 Bit 0 0 / 1 OFF - ON 0x0002 System of units → Imperial Bit 1 0 / 1 SI (Default) - Imperial Differential pressure...
PREMASGARD ® 232x - wModbus | Telegramms Function 08 Diagnostics The following sub function codes are supported Sub Function Answer Parameters Data Type Code Echo of transmission data Echo data (Loopback) Restart Modbus Echo telegram (Reset listen-only mode) Activation listen-only mode No answer Echo telegram Delete counter...
Important notes S+S Regeltechnik GmbH hereby declares that the radio equipment type 232x-wModbus complies with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.spluss.de/130112CF0910200/ This device can be mounted in any position. Pressure ranges (measuring ranges) are indicated on the device label. Applying measuring pressures beyond that range will cause mismeasurements and increased deviations or may destroy the pressure measuring transducer.
® PREMASGARD 232x - wModbus Rev. Data - V43 Sonde de pression sans entretien PREMASGARD ® 232x - wModbus (série) avec W-Modbus (Wireless), dans un boîtier plastique résistant aux chocs avec vis de fermeture rapide, manchon de raccordement pour tuyau de refoulement (Ø 6 mm), avec presse-étoupe (en option connecteur M12 selon DIN EN 61076-2-101), au choix avec ⁄...
Page 28
® PREMASGARD 232x - wModbus Rev. Data - V43 ® Schéma de montage PREMASGARD MODES DE SURVEILLANCE 232x - wModbus dépression P1 (+) n’est pas raccordé, ouvert côté air à l’atmosphère P2 (–) raccord à la conduite filtre P1 (+) raccord en amont du filtre P2 (–) raccord en aval du filtre ventilateur P1 (+) raccord en amont du ventilateur...
Page 29
® PREMASGARD 232x - wModbus Rev. Data - V43 ® ® Schéma de raccordement PREMASGARD Affectation des plots PREMASGARD 232x - wModbus 232x - wModbus de connexion (M12 en option) MALE offset DIP A 1 2 3 4 5 6 7 8 address Plug for display...
Page 30
W-Modbus (Wireless) | Mise en service (slave) Capteur W-Modbus (slave) LED D’ÉTAT Les deux LED L1 et L2 (à droite à côté du bouton Pair) indiquent l’état radio du capteur. Elles sont activées après la mise en marche et automatiquement désactivées après env. 30 minutes. Si nécessaire, les LED peuvent être réactivées manuellement à...
Page 31
Capteur W-Modbus (slave) APPRENTISSAGE (PAIRING) « Slave » L’adresse du bus est réglée sur « 1 » en usine et peut être modifiée à l’aide du commutateur DIP (voir section « Configuration Modbus »). Cette modification est possible à tout moment, même après le couplage à une passerelle. Pour la programmation par apprentissage d’un capteur W-Modbus (esclave) sur une Gateway maître (DDC/API), les deux appareils doivent être réglés sur le mode d’appairage (mode d’apprentissage).
Page 32
W-Modbus (Wireless) | Installation réseau Structure générale de la topologie en bus avec résistances de terminaison et de polarisation (forme mixte) MODBUS RTU-Master Résistance de pull-up / polarisation BIAS A (D1) D+ de ligne B (D0) D– Résistance de pull-down / polarisation BIAS Common...
Page 33
PREMASGARD ® 232x - wModbus | Configuration ADRESSE DU BUS L’adresse du bus est réglée sur « 1 » en usine et peut être modifiée à l’aide du commutateur DIP. Cette modification est possible à tout moment, même après le couplage à une passerelle. Dans le cas des appareils à...
PREMASGARD ® 232x - wModbus | Configuration AFFICHAGE SUR L‘ÉCRAN La valeur d’affichage dépend du système d’unités réglé (voir tableau « Fonction 05 Write Single Coil »). Si nécessaire, l’appareil peut être commuté de SI (par défaut) sur Impérial. Affichage standard Par défaut, la valeur est affichée sur la première ligne et l‘unité correspondante est affichée de manière statique sur la seconde ligne : Pression différentielle [Pa] [inWC] Affichage librement configurable Via l’interface Modbus, l’affichage de l’écran peut aussi bien être programmé...
Page 35
PREMASGARD ® 232x - wModbus | Configuration, Télégrammes Tableau des codes ASCII pour la zone d‘affichage de la matrice de points ASCII Sign ASCII Sign ASCII Sign ASCII Sign ASCII Sign Espace “ & < > ü ä Ä ö Ö...
Page 36
PREMASGARD ® 232x - wModbus | Télégrammes Function 05 Write Single Coil Registre Paramètres Data Type Value Range Autozero (Pression différentielle) 0x0001 Bit 0 0 / 1 OFF - ON 0x0002 Système d’unités → Impérial Bit 1 0 / 1 SI (Default) - Imperial Pression différentielle...
Page 37
PREMASGARD ® 232x - wModbus | Télégrammes Function 08 Diagnostics Les codes sous-fonction suivants sont pris en charge Code sous- Paramètres Data Type Réponse fonction Écho des données d’émission Données d’écho (loopback-rebouclage) Redémarrage Modbus (Reset Listen Télégramme d’écho Only Mode – Réinit Mode Écoute Seule) Activation Listen Only Mode Pas de réponse (mode Écoute seule)
Généralités S+S Regeltechnik GmbH déclare par la présente que le système radio de type 232x-wModbus est conforme à la directive 2014/53/EU. Le texte complet de la déclaration UE de conformité est disponible à l‘adresse Internet suivante : www.spluss.de/130112CF0910200/ La position de montage peut être choisie librement. Les plages de pression (plages de mesure) sont indiquées sur l’étiquette signalétique de l’appareil.
® PREMASGARD 232x - wModbus Rev. Data - V43 Не нуждающийся в техническом обслуживании датчик давления PREMASGARD ® 232x - wModbus (серия) с W-Modbus (Wireless), в ударопрочном пластиковом корпусе с быстрозаворачиваемыми винтами, со штуцером для напорного шланга (диаметр 6 мм), с резьбовым кабельным вводом (опционально...
Page 40
® PREMASGARD 232x - wModbus Rev. Data - V43 ® Схема монтажа PREMASGARD ВИДЫ КОНТРОЛЯ ДАВЛЕНИЯ: 232x - wModbus Контроль пониженного давления P1 (+) не присоединен, открыт для атмосферного воздуха P2 (–) присоединен к каналу Контроль фильтра P1 (+) включен перед фильтром P2 (–) включен после фильтра Контроль...
Page 42
W-Modbus (Wireless) | Ввод в эксплуатацию (ведомое устройство) Датчик W-Modbus (ведомое устройство) СВЕТОДИОДЫ СОСТОЯНИЯ Оба светодиодных индикатора L1 и L2 (справа возле кнопки Pair) показывают состояние радиосвязи датчика. Они активируются после включения и прибл. через 30 минут автоматически деактивируются. При необходимости светодиодные индикаторы можно активировать вручную с помощью кнопки Pair. СВЕТОДИОД...
Page 43
Датчик W-Modbus (ведомое устройство) ПРОГРАММИРОВАНИЕ (PAIRING) «Slave» На заводе настроен адрес шины «1», его можно изменить при помощи DIP-переключателей (см. пункт «Конфигурирование шины Modbus»). Изменение адреса возможно в любое время, даже после подключения к шлюзу. Для подключения датчика W-Modbus (ведомое устройство) к главному шлюзу (ПЦУ/ПЛК) нужно перевести оба устройства в...
Page 44
W-Modbus (Wireless) | Создание сети Общая структура шинной топологии с согласующими резисторами и резисторами в цепи смещения (гибридная форма) MODBUS RTU-Master Подтягивающий резистор / резистор в цепи смещения BIAS A (D1) D+ Оконечная нагрузка шины B (D0) D– Стягивающий резистор / резистор...
Page 45
PREMASGARD ® 232x - wModbus | Конфигурация А ДРЕС ШИНЫ На заводе настроен адрес шины «1», его можно изменить при помощи DIP-переключателей. Изменение адреса возможно в любое время, даже после подключения к шлюзу. На устройствах с дисплеем измененный адрес показывается в течение прибл. 30 секунд. Пример...
PREMASGARD ® 232x - wModbus | Конфигурация ИНДИК АЦИЯ НА ДИСПЛЕЕ Отображаемое значение зависит от настроенной системы единиц (см. таблицу «Функция 05 — Запись значения одного флага (Write Single Coil)»). При необходимости можно переключить устройство с СИ (по умолчанию) на английскую систему мер. Стандартная...
Page 47
PREMASGARD ® 232x - wModbus | Конфигурация, Телеграммы Таблица кодов ASCII для полей с точечной матрицей ASCII Sign ASCII Sign ASCII Sign ASCII Sign ASCII Sign Пробел “ & < > ü ä Ä ö Ö Ü ° Неуказанные в таблице символы ASCII или управляющие символы отображаются в виде пробела. ТЕЛЕГРАММЫ...
Page 48
PREMASGARD ® 232x - wModbus | Телеграммы Функция 05 — Запись значения одного флага (Write Single Coil) Регистр Параметры Тип данных Значение Диапазон Автоматический ноль (дифференциальное давление) 0x0001 бит 0 0 / 1 OFF - ON 0x0002 Система единиц СИ → Импер. ед. бит...
Page 49
PREMASGARD ® 232x - wModbus | Телеграммы Функция 08 — Диагностика (Diagnostics) Поддерживаются следующие коды подфункции Код Параметры Тип данных Ответ подфункции Эхо отправленных данных (Loopback) Данные эхо Перезапуск Modbus Телеграмма эхо (Reset Listen Only Mode) Активация (Listen Only Mode) Без ответа Сброс...
Page 50
Указания к продуктам Компания S+S Regeltechnik GmbH настоящим заявляет, что радиосистема типа 232x-wModbus соответствует Директиве 2014/53/EU. Полный текст декларации соответствия ЕС доступен по следующему интернет-адресу: www.spluss.de/130112CF0910200/ Установочная длина может быть любой. Диапазоны давлений (диапазоны измерения) указаны на этикетке/табличке прибора. Попытка измерения...
Page 51
Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
Page 52
D G U F r Busadresse, binärcodiert Bus address, binary coded Adresse du bus, code binaire Адресс шины, двоичный 0 0 0 0 0 0 0 1 0 0 1 1 0 0 1 1 0 1 1 0 0 1 0 1 1 0 0 1 0 1 1 1 1 1 0 0 1 0 0 1 0 0 0 0 0 0 1 0...