Connect 261670 Fts - Graco Gusmer Power-Lock 246045 Instructions - Parts Manual

Heated hose
Table of Contents

Advertisement

Installation

Connect 261670 FTS

CAUTION
Do not coil hose tighter than the minimum
bend radius of 3 ft (0.9 m). Do not subject
hose to excessive weight, impact, or other
abuse.
1. Carefully extend FTS probe (H) into the
hose section from the proportioner. Do not
bend or kink probe. Insert probe in major
volume (resin) side on systems which
are not 1:1 mix ratio.
2. Connect FTS (J) to mix manifold.
S
G
To
Proportioner
14
S
R
F
3. Connect fluid hoses to FTS (J).
To use 1/2 in. (13 mm) ID fluid hoses,
remove the adapters from the propor-
tioner fluid manifold and install them in
the FTS swivel inlets.
4. Install one connector (D) between wires.
Refer to page 10 for instructions.
5. Connect hose assembly cable (F) to FTS
cable (R). Slide insulator sleeves (S) over
connection. Leave slack (G) in cables as
stress relief, to prevent cable failure.
6. See Check Hoses for Leaks, page 15.
J
H
D
To Mix Manifold
(with no heated
whip hose)
TI2684D
309572S

Advertisement

Table of Contents
loading

Table of Contents