Hose - Graco Gusmer Power-Lock 246045 Instructions - Parts Manual

Heated hose
Table of Contents

Advertisement

Connect 261669 FTS and Heated Dual Whip Hose
CAUTION
To prevent damage to probe, do not kink or
excessively bend hose. Do not coil hose
tighter than the minimum bend radius of 3 ft
(0.9 m). Do not subject hose to excessive
weight, impact, or other abuse.
1. Carefully extend FTS probe (H) into the
hose section from the proportioner. Do not
bend or kink probe. Insert in component A
(ISO) side of main hose for foam or polyu-
rea systems.
2. Connect FTS (J) to whip hose (W).
3. Connect whip hose ground wire (K) to
ground screw on underside of FTS.
To Proportioner
S
G
309572S
S
R
F
B
A
4. Connect fluid hoses to FTS (J).
To use 1/2 in. (13 mm) ID fluid hoses,
remove the adapters from the propor-
tioner fluid manifold and install them in
the FTS swivel inlets.
5. Connect electrical connectors (D).
6. Connect air hose (C) to whip air hose (L).
7. Connect hose assembly cable (F) to FTS
cable (R). Slide insulator sleeves (S) over
connection. Leave slack (G) in cables as
stress relief, to prevent cable failure.
8. See Check Hoses for Leaks, page 15
D
K
J
H
C
B
A
L
Installation
To Gun
W
TI9581B
13

Advertisement

Table of Contents
loading

Table of Contents