Cleaning the inside of the nosepiece
1. Remove the fastener guide. → page 9
2. Clean the inside of the nosepiece.
3. Insert the fastener guide. → page 9
8
Transport and storage of cordless tools
Transport
CAUTION
Accidental starting during transport !
▶ Always transport your products with the batteries removed!
▶ Remove the battery.
▶ Transport the tool and batteries individually packaged.
▶ Never transport batteries in bulk form (loose, unprotected).
▶ Check the tool and batteries for damage before use after long periods of transport.
Storage
CAUTION
Accidental damage caused by defective or leaking batteries !
▶ Always store your products with the batteries removed!
▶ Store the tool and batteries in a place that is as cool and dry as possible.
▶ Never store batteries in direct sunlight, on heating units or behind a window pane.
▶ Store the tool and batteries in a place where they cannot be accessed by children or unauthorized
persons.
▶ Check the tool and batteries for damage before use after long periods of storage.
9

Troubleshooting

If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
Trouble or fault
The spring element is not ten-
sioned; no status indication.
The spring element is not ten-
sioned, the status indicator
blinks green and 1 battery
charge status LED blinks.
The spring element is not re-
tensioned, the status indica-
tor blinks green and 4 battery
charge status LEDs blink.
The spring element is not ten-
sioned and the status indica-
tor blinks red.
The spring element is not ten-
sioned and the status indica-
tor lights red.
The fastener guide cannot
be pressed in and the status
indicator lights green.
2184329
*2184329*
Printed: 19.07.2018 | Doc-Nr: PUB / 5377482 / 000 / 02
Possible cause
The battery is empty.
The battery is not fitted correctly.
The battery is empty.
Battery temperature too low.
The fastening tool has overheated.
The fastener guide is not fitted
correctly.
System fault.
The magazine is empty.
The nail pusher is jammed.
Action to be taken
▶ Change the battery.
▶ Insert the battery. → page 8
▶ Change the battery.
▶ Allow the battery to warm up
slowly to room temperature.
▶ Allow the fastening tool to cool
down.
▶ Insert the fastener guide.
→ page 9
▶ Remove the battery. → page 9
▶ Insert the battery. → page 8
▶ Load the magazine. → page 9
▶ Remove the nail strips from
the magazine and clean the
magazine.
English
13