6.2
Switching the fastening tool on/off
6.2.1
Switching on the fastening tool
WARNING
Risk of injury! Pressing the nosepiece of the fastening tool against a part of the body may lead to serious
injury due to inadvertent firing and release of a fastener.
▶ Never press the nosepiece of the tool against your hand or any other part of the body.
▶ Press the on/off button.
◁ The spring mechanism audibly builds up tension and the status indicator shows green.
When battery performance drops, tensioning of the spring mechanism takes longer than with a
fully charged battery.
Battery performance drops at low temperatures.
If you continue to operate the fastening tool after battery performance drops, the fastening tool
will switch itself off automatically before damage to the battery cells occurs.
6.2.2
Switching off the fastening tool
▶ Press the on/off button.
◁ The spring mechanism audibly relieves its tension and the status indicator goes out.
6.3
Driving a nail
7
WARNING
Risk of injury by flying parts! When driving a fastener, there is a risk of injury to the body and eyes caused
by splintered fragments of the workpiece and by flying parts of the nail strip.
▶ Wear personal protective equipment and always wear protective glasses and protective gloves.
Other persons in the vicinity must also wear eye protection and a hard hat.
WARNING
Risk of injury! Pressing the nosepiece of the fastening tool against a part of the body may lead to serious
injury due to inadvertent firing and release of a fastener.
▶ Never press the nosepiece of the tool against your hand or any other part of the body.
1. Switch on the fastening tool. → page 11
2. Hold the fastening tool perpendicular to the working surface and press it against the surface, pushing
the fastener guide in as far as it will go.
3. Drive the nail by pressing the safety trigger.
4. Lift the fastening tool completely clear of the working surface after driving a fastener.
The fastening tool switches itself off automatically if the fastener guide is pressed against the
working surface for longer than 6 seconds without a nail being driven. The fastening tool can be
switched on again by pressing the on/off button.
The fastening tool switches itself off automatically if it is not used for 6 minutes.
6.4
Switching off Bluetooth
▶ Press the on/off button for at least 5 seconds until the LED shows blue twice.
◁ No further data transfer is possible.
▽ Bluetooth is not available in all markets
Bluetooth can be deactivated if you are in a sensitive environment (e.g. a hospital) where use of
Bluetooth is prohibited.
6.5
Removing nails from the fastening tool
6.5.1
Removing a nail when in magazine mode
1. Pull the nail pusher down until it engages.
2184329