m. Taste the beverage to verify that there is no off taste.

5. OPERATION OF THE LFS

5.1

CONNECTIONS

A. Attach 3/8" syrup hoses between syrup (BIB), syrup pump, and the unit. Inlet syrup hose, 3/8",
attaches to left side of unit.
B. Attach CO
The unit recognizes the left side of the unit as syrup and right side as water.
FAILURE TO RUN UNIT WITHOUT WATER LINES CONNECTED WILL RESULT IN OVERHEAT
OF THE SOLENOID VALVES.
C. Attach water lines from water source or prechiller to the unit.
5.2

INITIAL POWER UP

A. Insure the switches on the unit are set to the middle (OFF) position.
B. Plug in the unit.
5.3

AUTO MODE

A. Switch the unit into AUTO Mode. The Green power
light will come on and the valve will start
dispensing syrup and water out of the valve.
5.4

MANUAL MODE

A. Switch the unit in MANUAL Mode (this requires
holding down the switch). The Green power light
will come on and the valve will start dispensing
syrup and water out of the valve.
5.5

SETTING THE DESIRED RATIO

A. ADJUSTING WATER FLOW
The Model 145 LEV
from 2.0 oz/sec (59.2 ml/sec) to 4.50 oz/sec
(133.2 ml/sec). The restricted flow adjustment plug
adjusts to a maximum flow of 3.3 oz/sec
(97.7 ml/sec).
1. Slide
adjustments are exposed (see Figure 2).
2. Remove nozzle by twisting counter clockwise and pulling down.
3. Remove diffuser by pulling down.
4. Install Lancer syrup separator (PN 54-0201, smoke, for Model 145 valves) in place of the
nozzle.
Mounting Block Stems in OPEN Position
connection to syrup pump.
2
water flow may be adjusted
®
I.D.
panel
UP until
SYRUP
WATER
STEMS
OPEN
FIgure 3
NOTE:
WARNING:
FLOW CONTROL
WATER
Increase
flow
control
Mounting Block Stems in CLOSED Position
4
I.D. PANEL
open position)
COVER SCREW
FLOW CONTROL
Decrease
Increase
NOZZLE (WITH
DIFFUSER INSIDE)
Valve Adjustment
Figure 2
SYRUP
WATER
STEMS
CLOSED
FIgure 4
(Shown in
SYRUP
Decrease

Advertisement

Table of Contents
loading

This manual is also suitable for:

85-0087

Table of Contents