Erratic Ratio O Brix; Product Dispensed; Water Only Dispensed, No Syrup, Or Syrup Only Dispensed, No Water; Valve Will Not Shut Off - lancer LEV FILL STATION Installation And Service Manual

Hide thumbs Also See for LEV FILL STATION:
Table of Contents

Advertisement

TROUBLE
o
6.12 Erratic Ratio
Brix.
6.13 No product dispensed.
6.14 Water only dispensed,
no syrup; or syrup only
dispensed, no water.

6.15 Valve will not shut OFF.

6.16 Excessive foaming.

CAUSE
A. Incoming water and/or syrup
supply not at sufficient
flowing pressure.
B. Foreign debris in water and/or B. Remove flow controls and clean
syrup flow controls.
A. Water and syrup shutoffs are
not fully OPEN.
B. Ensure cup lever arm, or I.D.
Panel actuator is actuating
switch.
C. Electric current not reaching
valve.
D. Improper or inadequate water
or syrup supply.
E. BIB empty.
A. Water or syrup stem on
mounting block not fully
OPEN.
B. Improper or inadequate water
or syrup supply.
A. Cup Lever may be sticking
or binding.
B. Switch not actuating properly.
C. Solenoid armature not
returning to bottom position.
D. Debris or damage to Paddle
arms.
A. Incoming water or syrup
temperature too high.
B. Water flow rate too high.
C. Nozzle and diffuser not clean.
D. Nozzle and diffuser not
properly installed.
E. CO
pressure too high.
2
NOTES:
7
REMEDY
A. Check incoming water and
syrup supply to ensure sufficient
flowing pressure.
out any foreign materials to ensure
smooth free piston movement.
A. Check stems on mounting block
to ensure they are in fully OPEN
position.
B. If not, repair or replace.
C. Check electric current supplied to
valve. See SPECIFICATIONS. If
current is adequate, check
solenoid coil and switch. Replace
if necessary.
D. Remove valve from mounting block
and open stems slightly and
check to ensure proper water and
syrup supply. If no supply, check
dispenser for freeze-up or other
problems.
E. Replace BIB.
A. Check stems on mounting
block to ensure they are in full
OPEN position.
B. Remove valve from mounting block
and open stem slightly to check
for proper syrup and water supply.
If no supply, check dispenser for
freeze-up or other problems.
A. Correct or replace lever.
B. Check switch for free actuation.
C. Replace defective solenoid
armature or spring.
D. Remove debris and/or replace
damaged paddle arms.
A. Correct at dispenser.
B. Readjust and reset
Section 5.5.
C. Remove and clean.
D. Remove and install properly.
E. Check for proper pressure setting.
o
Brix. See

Advertisement

Table of Contents
loading

This manual is also suitable for:

85-0087

Table of Contents