ADA STANDARDS FOR ACCESSIbLE DESIGN To assure that beverage service is accessible to all customers, Lancer recommends that counter height and equipment selection be planned carefully. The 2010 ADA Standards for Accessible Design states the maximum reach height from the floor should be no more than 48”...
The selected location should be able to support the weight of the unit. 1.4 ADA (AMERICANS WITH DISAbILITIES ACT) STANDARDS FOR ACCESSIbLE DESIGN To assure that beverage service is accessible to all customers, Lancer recommends that counter height and equipment selection be planned carefully.
LANCER MULTIFILL MKIII BEER SYSTEM 2. INSTALLATION 2.1 UNpACkING THE DISpENSER A. Set shipping carton upright on the floor. Cut band and remove. Remove any staples that secure the shipping board and lid to the carton. Open top of carton and remove interior packing.
INSTALLATION, OPERATION & SERVICE MANUAL PN 28-0889 3. bASIC pRINCIpLE OF OpERATION The Multifill System consists of seven basic components. 1. OPERATING BOARD: Group of two buttons to start and manually stop the dispense. 2. VALVE SELECTION BOARD: To select 1 – 4 valves for dispense. 3.
LANCER MULTIFILL MKIII BEER SYSTEM 3.2 pROGRAMMING THE MULTIFILL - CONTINUED L. This value will be programmed into the memory upon selection of next valve or when exiting the programming mode. M. Repeat steps 6-11 for remaining valves. N. When all levels have been set, turn key to dispense.
INSTALLATION, OPERATION & SERVICE MANUAL PN 28-0889 4. CLEANING AND SANITIZING INSTRUCTIONS GENERAL INFORMATION A. The cleaning and sanitizing procedures provided pertain to the Lancer equipment identified by this manual. If other equipment is being cleaned, follow the guidelines established by the manufacturer for that equipment.
LANCER MULTIFILL MKIII BEER SYSTEM 4.3 DAILY CLEANING A. Using the cleaning solution, clean Top Cover and all exterior stainless steel surfaces. B. Clean exterior. D. Wipe clean all splash areas using a damp cloth soaked in cleaning solution. E. Clean beverage valves as specified by the valve manufacturer.
INSTALLATION, OPERATION & SERVICE MANUAL PN 28-0889 6. SpARE pARTS button board Cables Button pad C/W CABLE Cable 5 core (Valves) Control Module General parts Valves Control Module 28V c/w cables Flow control Beer valve DC – ODL Bridge rectifier End cap – Black Coil DC - ODL Fuse –...
Page 12
LANCER MULTIFILL MKIII BEER SYSTEM 7. TROUbLESHOOTING - CONTINUED ISSUE CAUSE SOLUTION One or more A. Control module of transformer not A. Make sure that both units are switched on and valves not opening. switched on. both power LED’s on valve selection board are lit.
INSTALLATION, OPERATION & SERVICE MANUAL PN 28-0889 8. CHECkLIST Refrigerant decal supplied. Leak check all refrigeration components with the leak detector. Liquid line solenoid and suction line, check valve installed for correct flow direction. Correct orifice tag is applied to TX valve. ...
Page 14
LANCER MULTIFILL MKIII BEER SYSTEM LANCER To order parts, call Customer Service: 800-729-1500 Warranty/Technical Support: 800-729-1550 Email: custserv@lancercorp.com www.lancercorp.com...
Need help?
Do you have a question about the Multifill MkIII and is the answer not in the manual?
Questions and answers