1. SPECIFICATIONS
SHIPPING WEIGHT
DIMENSIONS
ELECTRICAL
INLET SYRUP CONNECTIONS
INLET WATER CONNECTIONS
FLOW

2. INSTALLATION

2.1

RECEIVING

Each unit is completely tested under operating conditions and thoroughly inspected before
shipment. At the time of shipment, the carrier accepts the unit and any claim for damage must be
made with the carrier. Upon receiving unit(s) from the delivering carrier, carefully inspect carton for
visible indication of damage. If damage exists, have carrier note same on bill of lading and file a
claim with the carrier.
2.2

UNPACKING

A. Carefully remove unit from shipping carton.
B. Inspect unit for concealed damage. If damage exists, notify delivering carrier note and file a
claim against the carrier.
2.3
INSTALLATION
DISCONNECT
INSTALLATION OF THE LANCER LEV
ELECTRICAL SHOCK OR SERIOUS INJURY.
Mounting
A. The dispenser is designed for in-door use ONLY and to be mounted on unit, in a well
lighted, visible area.
FAILURE TO MAINTAIN PROPER AIR CLEARANCE WILL CAUSE THE UNIT TO OVERHEAT AND
WILL RESULT IN PREMATURE COMPONENT FAILURE.
B. Locate slush machine with approximately five (5) inches clearance between a wall and the back
of the LFS unit. Follow slush machine manufacturer's installation instructions for side and rear
ventilation requirements.
C. If required, locate and mark four (4) holes using base of fill station (see Figure 1).
D. Cover hopper with lid before drilling holes.
ENSURE HOLES ARE CAREFULLY DRILLED TO AVOID DRILLING TOO DEEP AND THEREBY
POSSIBLY DAMAGING REFRIGERATION LINES.
E. Drill four (4) holes using a #19 drill bit (0.166) drill bit.
Nine (9) pounds (4.1 kg)
14.5" x 5.5" x 7.5" (36.83 cm x 13.97 cm x 19.05 cm)
115V/60Hz/1.0A
(Power Cord is provided with three prong grounded plug)
3/8 inch Male Flare
3/8 inch Male Flare
4.5 ounces per second
WARNING
SLUSH
MACHINE
Base Fill Assembly
Screw Mounting, Hole Pattern
CAUTION
CAUTION
FROM
POWER
SOURCE
FILL STATION (LFS) TO AVOID POSSIBLE FATAL
®
PN
30-3193
Figure 1