Section 3

Frost Top Serving Counter Operation

Frost top counters are designed to maintain an even layer
of frost to pleasantly display product. Once turned on, the
compressor will run continuously. There is no temperature
control. The ON/OFF switch is the only means available to
cycle the unit.
Since it takes time for the frost to accumulate initially, the
unit should be turned on approximately one hour before it
is required. Product should not be placed on the frost top
prior to turning the unit on, because it may freeze to the
surface of the unit.
The unit must be turned off when not in use or overnight
for defrosting and cleaning.
Refrigerated Cold Pan with LiquiTec Serving
Counter Operation
The cold pan is not intended to be used with ice.
There is a switch on the compressor housing front to turn
counters on and off. Turn it off when not in use or overnight
for defrosting and cleaning.
The are adjusted at the factory to provide proper operation
without any further adjustments.
ERC112 TEMPERATURE CONTROL & DISPLAY
Temperature displayed is for refrigeration set point
purposes only. Display does not reflect air or product
temps in unit.
1. At initial start-up or anytime power is disconnected,
then reconnected to the unit, the control will go into
normal cooling mode.
2. The temperature control will cycle the compressor and
condenser fan motor to maintain proper temperature.
Press upper or lower right button.
Display show actual set-point (blinking).
• If buttons untouched for 3 seconds returns to
normal.
Part Number: 9291493 REV00 06/20

Note
Notice
V
Increase set-point by pressing upper button. Max value
depends on parameters in control.
Decrease set-point by pressing lower button. Min value
depends on parameters in control.
• If buttons untouched for 3 seconds returns to
normal and stores new set-point.
Press lower left button for 5 seconds.
Unit goes into stand-by mode.
• The display will read Off, then a period.
Press the lower left button again for 5 seconds.
• The display will read On.
• The unit will then start up in normal cooling
mode.
Operation / Indication
Status
Displayed
Normal (°C)
Temp.
Normal (°F)
Temp. [°F]
Show set-point
Temp.
Sensor 1 defect
E01
Sensor 2 defect
E02
Sensor 3 defect
E03
Sensor 4 defect
E04
High temperature
alarm
Low temperature
Lo
alarm
Line voltage too high
uHi
Line voltage too low
uLi
Control calls for
LEA
cooling for more than
24 hours straight
Temperature Alarm
The alarm will sound and flash HI or LO 90 minutes after the
unit has reached its alarm temperature point or after any
power interruption if the temperature is above or below the
alarm set points.
Operation
Comments
Unit depends on
[°C]
setting (parameters in
control)
X
Air sensor
X
Open
X
Open
X
Open
X
Automatically
Hi
switching at 2 sec rate
X
X
X
X
Time includes defrost.
Error will go away
if the control cycles
off the compressor
or if the power is
shut off. If error is on
a cold pan it could
be related to a high
ambient temperature
or not shutting the
rail off nightly.
17