Section 2
OPTION REFRIGERATION
Option
Self Contained Combination Hot/Cold Food Wells
N8630P
N8643P
N8656P
N8669P
N8681P
Individually Controlled Energy Savings Heated Food Wells
DESP Series
Part Number: 9291493 REV00 06/20
BTU/Hour
Heat of
Capacity
Rejection
Charge in
1112
379
1259
569
1373
758
1469
948
1787
1138
NA

Leveling

After the cabinet has been placed in the desired location,
R290
cabinets with legs must be leveled. Level units from front to
grams
back and from side to side. Leveling will insure proper door
operation and removal of condensate. Cabinets with casters
120g
must have the caster brake set so the cabinet cannot move.
120g
120g

Stabilizing

120g
150g
It is very important that all legs are properly adjusted to
keep the cabinet level, evenly distribute the weight and to
make sure the unit will not rock, lean or be unstable.
Leg & Caster Installation
Legs or casters must be installed and the legs or casters
must be screwed in completely to prevent bending.
When casters are installed the mass of this unit will
allow it to move uncontrolled on an inclined surface.
These units must be tethered/secured to comply with
all applicable codes.
The unit must be installed in a stable condition with
the front wheels locked. Locking the front casters after
installation is the owner's and operator's responsibility.
Use a jack to lift the refrigeration unit off the ground
just far enough to remove the leg/caster. Place blocking
underneath the unit. Do not work underneath a raised
unit without proper blocking. Do not lift the unit more
than necessary to remove the leg/caster. Lifting the unit
too far can make the unit unstable.
All single-section units require that the swivel casters be
mounted on the front and rigid casters be mounted on
the rear.

Accessory Installation

Over shelves and other items mounted to the top of the
counters should never be installed in the field due to the
potential damage to the refrigeration system.
DANGER