IPT*-FP WITH U-P6-B5-V

Technical specifications

8
Technical specifications
8.1

Read/write station IPT*-FP

IPT*-FP
General data
Operating frequency
Transfer rate
Operating distance
Display/controls
LED green
LED yellow
LED red
Electrical data
Rated operating voltage U
Power consumption P
Galvanic isolation
Operating voltage/Interface
Interface
Physical
Ambient conditions
Ambient temperature
Storage temperature
Mechanical data
Degree of protection
Housing material
125 kHz
2 kBit/s
max. 100 mm
Power on
IPC recognized
Bus error (with the use of field bus
interfaces)
20 ... 30 V DC, ripple 10 %
e
max. 5 W, in connection with lower section
0
Functional isolation in accordance with DIN
EN 50178, rated isolation voltage 50 V
Interface type depends on the lower section
used
-25 ... 70 °C (248 ... 343 K)
-40 ... 85 °C (233 ... 358 K)
IP67 in accordance with IN 60529, in
connection with lower section
PBT (Polybutylene terephthalate)
, PELV
SS