IPT*-FP WITH U-P6-B5-V
Operation on the INTERBUS
7.8
Legend
<ConfAddr>
<Data>
<ExecCounter>
<FixLen>
<FixType>
<IDCode>
Mode <F>
<Parameter>:
<PSW>
<RegAddr>:
<Status>
<T>
<TagType>
<VersionData>
<WordAddr>
<WordNum>
:
Word start address in the configuration range of the data
carrier.
1 ASCII character range from "0" to "F", depending on data
carrier type.
The following applies for IPC03:
"1" = Protection Word
"2" = Control Word
:
<WordNum> times 4 Bytes. When communicating a word,
the highest value byte is transferred first and the lowest
value byte last.
:
1 byte
:
4 Bits
:
2 ASCII characters, for example: for IPC02 "02" (32h 30h)
:
4 bytes for IPC03
5 bytes for IPC02 and IPC11
:
1 ASCII character "0" or "1" .
:
1 Byte, range of values 01h to 08h
:
4 Bytes, password
:
4 Bytes
:
1 byte
:
1 Bit 0 (0b); 1(1b)
:
2 ASCII characters, for example: '02' for IPC02
:
6 ASCII characters, software version message
:
4 Bytes
Word start address in the data carrier, range from "0000"
to "FFFF", depending on data carrier type.
:
4 Bits
Number of words to be read or written, 01h ("0001") is used
as number of words.
The following applies for IPC03:
The number of words 00h is used with the word address
"0000" to read the preset data range on the data carrier.
55