Pepperl+Fuchs IDENT-I system P IPT FP Series Manual page 53

Read/write station with interbus interface
Table of Contents

Advertisement

IPT*-FP WITH U-P6-B5-V
Operation on the INTERBUS
Buffered Write Fixcode
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
.
.
.
Byte 9
Response:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
.
.
.
Byte 9
One attempt is made to write a fixcode. After each successful write, the response is sent and
the system waits until a new data carrier is within the detection range. The command then
starts again from the beginning.
Content
Command code
FixLen/Toggle bit
FixType
FixType
Data 00 ... FF
h
Data 00 ... FF
h
Data 00 ... FF
h
Content
Command code
FixLen/Toggle bit
Status
Execution counter
not relevant
.
.
.
not relevant
B7
B6
B5
B4
B3
0
1
1
0
0
<FixLen>
-
<FixType> (High Byte)
<FixType> (Low Byte)
<Data>
<Data>
<Data>
B7
B6
B5
B4
B3
0
1
1
0
0
<FixLen>
-
<Status>
<ExecCounter>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
B2
B1
B0
1
0
1
-
-
T
B2
B1
B0
1
0
1
-
-
T
-
-
-
-
-
-
-
-
-