FACTORY AUTOMATION
MANUAL
IPT*-FP WITH U-P*-R4
Read/write station
with addressable
serial interface

Advertisement

Table of Contents
loading

Summary of Contents for Pepperl+Fuchs IPT FP Series

  • Page 1 FACTORY AUTOMATION MANUAL IPT*-FP WITH U-P*-R4 Read/write station with addressable serial interface...
  • Page 2 IPT*-FP WITH U-P*-R4 With regard to the supply of products, the current issue of the following document is appli- cable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotech- nik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"...
  • Page 3: Table Of Contents

    IPT*-FP WITH U-P*-R4 Introduction ..............5 Declaration of conformity........... 6 CE conformity ....................6 Safety ................7 Symbols relevant to safety ...............7 Intended use ....................7 General safety instructions ..............7 Product description ............ 8 Product family....................9 4.1.1 Code/data carrier..................9 Range of application ................10 Delivery package ..................
  • Page 4 IPT*-FP WITH U-P*-R4 Technical specifications ...........29 Read/write station IPT*-FP ..............29 Read/write distances IPT*-FP ..............30 Lower sections..................31...
  • Page 5: Introduction

    Introduction Introduction Congratulations You have chosen a device manufactured by Pepperl+Fuchs. Pepperl+Fuchs develops, produces and distributes electronic sensors and interface modules for the market of automation technology on a worldwide scale. Before you install this device and put it into operation, please read the operating instructions thoroughly.
  • Page 6: Declaration Of Conformity

    IPT*-FP WITH U-P*-R4 Declaration of conformity Declaration of conformity CE conformity This product was developed and manufactured under observance of the applicable European standards and guidelines. Note! A declaration of conformity can be requested from the manufacturer.
  • Page 7: Safety

    If serious faults occur, stop using the device. Secure the device against inadvertent operation. In the event of repairs, send the device to Pepperl+Fuchs. The connection of the device and maintenance work when live may only be carried out by a qualified electrical specialist.
  • Page 8: Product Description

    IPT*-FP WITH U-P*-R4 Product description Product description The brand name IDENT-I System P represents a complete identification system. The read/write station consists of the read/write head IPT*-FP (standard version: IPT1-FP) and the lower section U-P*-R4 with addressable serial interfaces RS485. With the use of 125 kHz technology, the system is extensively open for the implementation of other components.
  • Page 9: Product Family

    IPT*-FP WITH U-P*-R4 Product description Product family The inductive identification system IDENT-I system P from Pepperl+Fuchs offers various possible combinations of individual components. Read/write station Lower sections Code/data carrier Note! Detailed information on the components of the identification system IDENT-I system P can be found in the sensor systems 1 catalog.
  • Page 10: Range Of Application

    IPT*-FP WITH U-P*-R4 Product description Range of application The system is suited for the following applications: • Automation • Material flow control in production • Acquisition of operating data • Access control • Identification of e.g. storage vessels, pallets, work piece carriers, refuse containers, tanks, containers, etc.
  • Page 11: Display And Controls

    IPT*-FP WITH U-P*-R4 Product description Display and controls The following displays and controls are located on the read/write head. LED display Bus error - red IPC recognized - yellow, command executed successfully (approx. 1 second) Power on - green Interfaces and connections The following interfaces and connections are located on the lower section U-P*-R4: DIP-switch address...
  • Page 12: Installation

    Device type and version in accordance with the type plate • Accessories • Manual/manuals Retain the original packaging in case the device must be stored or shipped again at a later date. Should you have any questions, please direct them to Pepperl+Fuchs.
  • Page 13: Commissioning

    IPT*-FP WITH U-P*-R4 Commissioning Commissioning General information on commissioning Warning! Before commissioning, ensure that the plant is not in danger relating to device malfunction, e.g. from uncontrollable triggered processes. Note! Before commissioning, check once again that the connections are correct. After connecting the supply voltage, the green LED must illuminate.
  • Page 14: Command Overview

    IPT*-FP WITH U-P*-R4 Commissioning 6.2.1 Command overview The commands in the list are described in detail on the following pages. System commands Abbrevi Command code Command description ation 240d get data version quit change tag configure interface reset configuration store Standard read/write commands Read data Abbrevi...
  • Page 15 IPT*-FP WITH U-P*-R4 Commissioning Special command modes IPC03 configuration Abbrevi Command code Command description ation single write configure auto write configure buffered write configure 102d enhanced buffered write configure single get configuration auto get configuration buffered get configuration 104d enhanced buffered get configuration Password mode with IPC03 Abbrevi Command code...
  • Page 16: System Commands

    IPT*-FP WITH U-P*-R4 Commissioning 6.2.2 System commands get data This command retrieves the data from the read station. Data is only available for read commands. The data component is missing for write commands. Command: gd <DeviceNo> <CHCK> <ETX> Response: <Status> <DeviceNo> <ExecCounter>{<Data>}<CHCK>...
  • Page 17 IPT*-FP WITH U-P*-R4 Commissioning Change Tag This command tells the read station, which tag to communicate with. The read station status on delivery is Type “00” . Command: "ct“ <DeviceNo> <TagType> <CHCK> <ETX> Response: <Status> <DeviceNo> <CHCK> <ETX> The following data carrier types are currently supported: Data carrier- Descrip- Chip-Typ...
  • Page 18 IPT*-FP WITH U-P*-R4 Commissioning Configure Interface This command sets the timeout and the baud rate. The values are stored in a non-volatile manner. A change always requires a reset to take effect. The timeout indicates the amount of time, after which the device no longer waits for more characters in a command.
  • Page 19: Read/Write Commands

    IPT*-FP WITH U-P*-R4 Commissioning 6.2.3 Read/write commands Code or data Address range Data range Storage size in carrier Access <WordAddr> <WordNum> bytes IPC01 Read/write 0000...0017 01...18 IPC02 Fixcode IPC03 Read/write 0000...001C 01...1D IPC03 Fixcode IPC10 Read/write Single Read Words: One attempt is made to read <WordNum> 32-bit words from the address <WordAddr> . Command: “sr”...
  • Page 20 IPT*-FP WITH U-P*-R4 Commissioning Single Write Words: One attempt is made to write <WordNum> 32-bit words from the address <WordAddr>. Command: "sw“ <DeviceNo> <WordAddr> <WordNum> <Data> <CHCK> <ETX> Response: <Status> <DeviceNo> <CHCK> <ETX> Auto Write Words: Repeated attempts are made until <WordNum> 32-bit words are written from the address <WordAddr>.
  • Page 21: Ipc03 Configuration Commands

    IPT*-FP WITH U-P*-R4 Commissioning Auto Read Fixcode: An attempt is made until successful, to read a fixcode. Command: "af“ <DeviceNo> <CHCK> <ETX> Response: <Status> <DeviceNo> <CHCK> <ETX> Buffered Read Fixcode: The fixcode continues to be read. Only changing data is transferred via the interface. Command: "bf“...
  • Page 22 IPT*-FP WITH U-P*-R4 Commissioning The IPC03 has one “protection word” and one “control word” . With the “protection word” , a read- protected and a write-protected range can be defined. For this, each start and end of a read- protected and a write-protected range can be defined. With the “control word” , various operating modes and the read range for the “default read”...
  • Page 23 IPT*-FP WITH U-P*-R4 Commissioning IPC03 password mode It is possible to protect the control word and the protection word from being overwritten. Then the configuration can no longer be changed. The password mode serves this purpose. With password mode active in the data carrier, the data range of a data carrier can only be read or written after the correct password is sent to the data carrier from the read/write head.
  • Page 24 IPT*-FP WITH U-P*-R4 Commissioning Auto Write Configuration: Repeated attempts are made until successful, to read a word in the configuration range from the address <ConfAddr> . Command: “ac” <DeviceNo> <ConfAddr> <Data> <CHCK> <ETX> Response: <Status> <DeviceNo> <CHCK> <ETX> Buffered Write Configuration: One attempt is made to write a word in the configuration range from the address <ConfAddr>.
  • Page 25: Ipc03 Password Mode

    IPT*-FP WITH U-P*-R4 Commissioning Buffered Get Configuration: An attempt is made until successful, to read a word in the configuration range (“protection word” or “control word”) from the address <ConfAddr>. Only changing data is transferred via the interface. Command: “bg” <DeviceNo> <ConfAddr> <CHCK> <ETX>...
  • Page 26: Write Fixcode

    IPT*-FP WITH U-P*-R4 Commissioning Passwort Change This command changes the password in a data carrier. Here, first the old and then the new password has to be entered. If the password has been successfully written, then the password in the read station is also changed. The command password set is no longer necessary. The password of the IPC03 can also be changed with password mode inactive.
  • Page 27 IPT*-FP WITH U-P*-R4 Commissioning Buffered write fixcode One attempt is made to write a fixcode. After each successful write, the response is sent and the system waits until a new data carrier is within the detection range. The command then starts again from the beginning.
  • Page 28: Legend

    IPT*-FP WITH U-P*-R4 Commissioning 6.2.7 Legend <CHCK>: 1 ASCII character, 8-bit checksum with the addition of all preceding characters, without overrun. <ConfAddr>: Word start address in the configuration range of the data carrier. 1 ASCII character range from "0" to "F", depending on data carrier type.
  • Page 29: Technical Specifications

    IPT*-FP WITH U-P*-R4 Technical specifications Technical specifications Read/write station IPT*-FP IPT*-FP General data Operating frequency 125 kHz Transfer rate 2 kBit/s Operating distance max. 100 mm Display/controls LED green Power on LED yellow IPC recognized LED red Bus error (with the use of field bus interfaces) Electrical data Rated operating voltage U...
  • Page 30: Read/Write Distances Ipt*-Fp

    IPT*-FP WITH U-P*-R4 Technical specifications Dimensions of the read/write station Read/write distances IPT*-FP Distances Data carrier type in air Read distance with IPC02-20W 0 mm...40 mm Read distance with IPC02-30W 0 mm...50 mm Read distance with IPC02-50W 0 mm...80 mm Read distance with IPC02-C1 0 mm...80 mm...
  • Page 31: Lower Sections

    IPT*-FP WITH U-P*-R4 Technical specifications Lower sections U-P3-R4 U-P4-R4 Display/controls DIP switches Set the station address bus terminator ON = active OFF = inactive Electrical data Rated operating voltage U 20 ... 30 V DC, ripple 10 % , PELV Power consumption P max.
  • Page 32 IPT*-FP WITH U-P*-R4 Technical specifications U-P3-R4 Lower section M20 x 1.5 ø5.3 U-P4-R4 lower section 1/2" NPT ø5,3 U-P*-R4 Electrical connection DIP-switch address 1 MSB 5 LSB Terminating 24 V DC resistor B RS 485 Cable gland...
  • Page 33 IPT*-FP WITH U-P*-R4 Technical specifications...
  • Page 34 Twinsburg, Ohio 44087 · USA Tel. +1 330 4253555 E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No. 199003130E Singapore 139942 Tel. +65 67799091 E-mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com Subject to modifications TDOCT-0236AENG 098407 Copyright PEPPERL+FUCHS • Printed in Germany 04/2009...