Kenwood NX-720 Service Manual page 82

Vhf digital transceiver
Hide thumbs Also See for NX-720:
Table of Contents

Advertisement

NX-720
Receiver Section
Item
Panel tuning mode
1.AF level
[Panel test mode]
setting
1) CH-Sig: 1-1
SSG output:
–47dBm (1mV)
(MOD: 1kHz/±1.5kHz)
Wide 5k/Narrow:
Narrow
Beat Shift:
Uncheck
Compander:
Uncheck
2. Sensitivity 1 This adjustment
can be performed
only PC test mode.
3. Sensitivity 2 This adjustment
can be performed
only PC test mode.
4. RSSI
1) Adj item: [RRSS]
reference
Adjust: [.]
*5
2) Adj item:
[R.RSS]
[R.R.SS]
[Analog
[R.R.S.S]
Narrow]
[R.R.S.S.]
[R.R.S.S._.]
SSG output: 12dB
SINAD level -3dB
(MOD: 1kHz/±1.5kHz)
82
ADJUSTMENT
Condition
PC test mode
equipment
1) Test Channel
SSG
Channel: 1
DVM
Test Signaling
AF VM
Mode: Analog
4
Signaling: 1
Dummy
Wide 5k/Narrow:
load
Narrow
Oscillo-
Beat Shift: Uncheck
scope
Compander:
Uncheck
SSG output:
–47dBm (1mV)
(MOD: 1kHz/±1.5kHz)
1) Adj item:
SSG
[Sensitivity 1]
AF VM
2) Adj item: [Low],
4
[Low'], [Center],
Dummy
[High'], [High]
load
Press [Apply All]
Distortion
button to store the
meter
adjustment value.
Oscillo-
scope
1) Adj item:
SSG
[Sensitivity 2]
AF VM
2) Adj item: [Low],
4
[Low'], [Center],
Dummy
[High'], [High]
load
Press [Apply All]
Distortion
button to store the
meter
adjustment value.
Oscillo-
scope
1) Adj item:
SSG
[RSSI Reference
AF VM
(Analog Narrow)]
4
2) Adj item: [Low],
Dummy
[Low'], [Center],
load
[High'], [High]
Distortion
SSG output: 12dB
meter
SINAD level –3dB
Oscillo-
(MOD: 1kHz/±1.5kHz)
scope
Measurement
Test-
Unit
Terminal
Unit
ANT
Ext.SP
con-
nector
ANT
Ext.SP
con-
nector
ANT
Ext.SP
con-
nector
ANT
Ext.SP
con-
nector
Adjustment
Parts
Method
[Panel
Volume Up/Down
2.83V±0.3V
tuning
Key to obtain
(Volume Button in PC
mode]
2.83V AF output.
test mode screen)
[ ],
(2.0W @ 4 load)
[ ]
[PC test
mode]
[
],
[
]
[PC test
Write the value as
Increase the adjust-
mode]
followings,
ment value from the
[Low]: 61 (Preset)
preset value to get
[
],
[Low']: 85 (Preset)
12dB SINAD.
[
]
[Center]: 103
SSG output: -119dBm
(Preset)
(0.25uV)
[High']: 122
(Mod: 1kHz/±1.5kHz)
(Preset)
Note:
[High]: 152
The fi xed value of
(Preset)
Sensitivity 2 must be
written before adjust-
ing Sensitivity 1.
[PC test
Write the value as
mode]
followings,
[Low]: 48 (Fixed)
[
],
[Low']: 75 (Fixed)
[
]
[Center]: 104
(Fixed)
[High']: 132 (Fixed)
[High]: 187 (Fixed)
[Panel tuning mode]
After input signal
from SSG, press
[
] key to store
the adjustment
value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Specifi cations/
Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-720 c