Kenwood NX-720 Service Manual page 60

Vhf digital transceiver
Hide thumbs Also See for NX-720:
Table of Contents

Advertisement

NX-720
Adjusutment
Order
item
20
RSSI Reference
21
Open Squelch
22
Low RSSI
23
High RSSI
24
Tight Squelch
*1: Because NXDN Narrow is adjusted by adjusting Analog Narrow, it is not necessary to adjust NXDN Narrow.
■ Panel tuning mode fl ow chart
Note: In this Panel tuning mode fl ow chart, the Adjustment item name is modifi ed.
Panel test mode
[
] hold
High Transmit Power Limit
HLMT
[
] press
[
] hold
Low Transmit Power Limit
LLMT
[
] press
[
] hold
High Transmit Power
HPWR
[
] press
[
] hold
Low Transmit Power
LPWR
[
] press
[
] hold
Balance
BAL
[
] press
[
] hold
NXDN Deviation
NDEV
[
] press
[
] hold
Analog MAX Deviation
ADEV
[
] press
[
] hold
QT Deviation
QT
[
] press
[
] hold
DQT Deviation
DQT
[
] press
60
ADJUSTMENT
AW
Panel
PC
(Analog Wide)
tuning
test
5
5
5
5
5
Adjustment Item
LCD Display
[ ]
For all adjustment items, press the
[
] key to write the adjustment value.
[ ]
5 reference level
Narrow
Adjustments
[ ]
5 reference level
Narrow
Adjustments
[ ]
5 reference level
Narrow
Adjustments
[ ]
5 reference level
Narrow
Adjustments
[ ]
5 reference level
Narrow
Adjustments
[ ]
NXDN Deviation
Narrow
NDEV
[ ]
[ ]
Analog MAX Deviation
Narrow
ADEV
[ ]
[ ]
QT Deviation
Narrow
QT
[ ]
DQT Deviation
Narrow
DQT
AN
NN
(Analog Narrow)
(NXDN Narrow)
Adjustment range
5
- *1
1~256
5
- *1
1~256
5
- *1
1~256
5
- *1
1~256
5
1~256
N/W/VN
Very
Narrow
[ ]
5 reference level
Adjustments
Wide
[ ]
5 reference level
Adjustments
Wide
Wide
NV (NXDN Very
Narrow)
5
5
5
5
-
-
Adjustment Point
LCD Display
5 reference level
Low
Adjustments
L
Low-Center
L'
Center
C
Center-High
H'
High
H
5 reference level
Adjustments exit
Adjust item
Number
Receiver
Section 4
Receiver
Section 5
Receiver
Section 6
Receiver
Section 7
Receiver
Section 8
[ ]
[
]
[ ]
[
]
[ ]
[
]
[ ]
[
]
[ ]
[
]