NX-720
Item
Panel tuning mode
4. Maximum
1) Adj item: [NDEV]
Deviation
Adjust: []
(NXDN) *3
PTT : ON
Press [
] key to
[Very
store the adjust-
Narrow]
ment value.
5. Maximum
1) Adj item: [ADEV]
Deviation
Adjust: [.]
(Analog) *3
Deviation meter
LPF: 15kHz
[Narrow]
HPF: OFF
PTT: ON
Press [
] key to
store the adjust-
ment value.
[Wide]
1) Adj item: [ADEV]
Adjust: [...]
PTT: ON
Press [
] key to
store the adjust-
ment value.
*3: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 80.
Regarding Maximum Deviation (Analog), it is common with the adjustment of all analog signalings.
6. QT
1) Adj item: [QT]
Deviation *4
Adjust: [.]
Deviation meter
[Narrow]
LPF: 3kHz
HPF: OFF
PTT: ON
Press [
] key to
store the adjust-
ment value.
74
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Maximum
Deviation
Deviation (NXDN
meter
Very Narrow)]
Oscillo-
PTT: Press
scope
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [Maximum
Deviation
Deviation (Analog
meter
Narrow)]
Oscillo-
Deviation meter
scope
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [Maximum
Deviation (Analog
Wide)]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [QT
Deviation
Deviation (Analog
meter
Narrow)]
Oscillo-
Deviation meter
scope
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Measurement
Test-
Unit
Terminal
Unit
ANT
ANT
ANT
Adjustment
Parts
Method
[Panel
Write Reference
1311~1363Hz
tuning
value "513" for
[PC test mode]
mode]
each adjustment
[
],
point. Transmit at
Press [Apply All]
each adjustment
button to store the
[
]
point and check
adjustment value
[PC test
that the Analog
after all adjustment
mode]
deviation is be-
point was adjusted.
tween 1311Hz and
[
],
1363Hz.
[
]
[Panel
Write Reference
2050~2150Hz
tuning
value "513" for
mode]
each adjustment
[PC test mode]
point. Transmit at
Press [Apply All]
[
],
each adjustment
button to store the
[
]
point and check
adjustment value
[PC test
that the Analog
after all adjustment
mode]
deviation is be-
point was adjusted.
tween 2050Hz and
[
],
2150Hz.
[
]
Write Reference
4150~4250Hz
value "513" for
each adjustment
[PC test mode]
point. Transmit at
Press [Apply All]
each adjustment
button to store the
point and check
adjustment value
that the Analog
after all adjustment
deviation is be-
point was adjusted.
tween 4150Hz and
4250Hz.
[Panel
Write the value
0.35kHz±0.05kHz
tuning
513
mode]
(Reference value)
[
],
[
]
[PC test
mode]
[
],
[
]
Specifi cations/
Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-720 c

Table of Contents