elero RolTop S Operating And Installation Manual

elero RolTop S Operating And Installation Manual

Roller shutter drive 120 v / 60 hz

Advertisement

Quick Links

Roller shutter drive RolTop
120 V / 60 Hz

Table of contents

Operating and installation
1
instructions
2
2.1
2.2
2.3
2.4
2.5
3
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
4
5
5.1
5.2
5.3
5.4
5.5
5.6
5.6.1
5.6.2
5.6.3
5.6.4
5.6.5
5.6.6
5.6.7
5.6.8
5.6.9
Upper end position freely confi gurable,
5.7
Technical data
6
Troubleshooting
1
7
Servicing
8
Cleaning
1
9
Repair
1
10
Address
2
11
Disassembly and disposal
2
12
EC Declaration of Conformity
2
13
EN: Addendum to the manual
2
UL approval
2
14
FR: Addendum au manuel
2
Homologation UL
2
3
3
Roller shutter drive RolTop
3
120 V / 60 Hz
3
1
Operating and installation
4
instructions
4
Please keep these operating instructions for later use and
have them available during the complete service life of the
4
product!
4
The German version of these operating instructions is
the original version.
4
All foreign language documents are translations of the
5
original version.
5
All rights reserved with regard to patent claim or submission
of design or utility patent.
6
2

General information

6
The structure of these operating instructions is based on
6
the service life phases of the electrical drive (subsequently
referred to as product).
6
The manufacturer reserves the right to make changes to the
6
technical data included in these operating instructions. The-
se may deviate from the respective model of the product
6
while the factual information are generally not changed and
are not losing their validity. The current state-of-the-art can
6
be obtained from the manufacturer at all times. Potential
claims cannot be asserted. Deviations from text and pictori-
6
al statements are not possible and depending on the tech-
nical development, setup and accessories of the product.
6
Deviating information on special models are included by the
manufacturer in the sales documentation. Other information
shall remain unaffected by this.
7
2.1

Standards and guidelines

During system design, basic safety and health requirements
7
of applicable laws, standards and guidelines were obser-
ved. The safety is confi rmed by means of the Declaration
7
of Conformity (refer to „EC Declaration of Conformity"). All
safety information in these operating instructions are based
on currently applicable laws and regulations in Germany.
All information in the operating instructions must be obser-
8
8
8
8
8
8
8
8
9
9
9
138186501_US+CA_0513

Advertisement

Table of Contents
loading

Summary of Contents for elero RolTop S

  • Page 1: Table Of Contents

    Roller shutter drive RolTop 120 V / 60 Hz Table of contents Technical data Troubleshooting Operating and installation instructions Servicing Cleaning General information Repair Standards and guidelines Address Intended use Disassembly and disposal Foreseeable misuse EC Declaration of Conformity Warranty and liability EN: Addendum to the manual Customer service of the manufacturer UL approval...
  • Page 2: Intended Use

    In case of a defect, the product may only be repaired by the manufacturer. Please refer to section „Address“ for the return address of the customer service. If you did not acquire the product directly from elero, please contact your supplier. 2 | US+CA...
  • Page 3: General Safety Principles

     Without approval by the manufacturer, no modifi cation, requirements of the product. extensions or alterations must be carried out on the product. © elero GmbH US+CA | 3...
  • Page 4: Safety Instructions On Transport, Assembly And Installation

    During operation it carries out radial movements. unhooked unsupervised.  Commissioning of the RolTop with elero installation cable  Standing under suspended loads is forbidden. for setting of various functions.  During loading with hoisting equipment, a safety helmet ...
  • Page 5: Mechanical Mounting

    Attach the RolTop only to the provided mounting elements. Firmly mounted control units must be visible attached. • The fabric must be mounted on the winding shaft. Fig. 4 Removing and inserting the device plug © elero GmbH US+CA | 5...
  • Page 6: Connection Example, Roltop 120 V / 60 Hz

    This is always carried out in pairs (upper and lower On delivery, the drive system is set to commissioning mode. end position at once). ►It is necessary to set the end positions with the elero By deleting the end positions, also the setting of the optio- installation cable.
  • Page 7: Option A: Upper And Lower End Position Freely Confi Gurable

    The lower end position is set. Optional: Activation of the relief function for the lower limit stop: refer to section 5.6.3. End position setting of option C is completed. Fig. 10 End position setting option C: © elero GmbH US+CA | 7...
  • Page 8: Option D

    After the last use, dispose of the product according to appli- triggered down cable regulations. Environmental information No unnecessary packaging material was used. Packaging can be separated into three material types: Cardboard (carton), polystyrene (padding) and polyethylene (bag, protective foam foil). 8 | US+CA © elero GmbH...
  • Page 9 Wir erklären hiermit, dass das/die nachfolgend genannte/n Produkt/e der Maschinenrichtlinie 2006/42/EG entspricht/entsprechen. Rohrmotor Produktbezeichnung: • RolTop S (120V/60Hz) alle Varianten • RolTop M (120V/60Hz) alle Varianten Beschreibung: Einsteckantrieb für Rollläden Die Übereinstimmung der/s bezeichneten Produkte/s mit den wesentlichen Schutzanforderungen wird durch Einhaltung folgender Richtlinien und Normen berücksichtigt:...
  • Page 10 GmbH Linsenhofer Straße 65 Phone: +49 7025 13-01 info@elero.de Technical modifications reserved Antriebstechnik D-72660 Beuren Fax: +49 7025 13-212 www.elero.com...

This manual is also suitable for:

Roltop m

Table of Contents