Keep these instructions in a safe place!
After installation of the tubular drive attach these instructions
to the cable for the electrician.
Device functions:
• Blind protection (torque limiting)
• Commissioning the drive with the assembly cable.
As-delivered condition (commissioning mode)
• Setting end positions
Important safety instructions!
Observe the following instructions.
Risk of injury due to electrocution.
The connections to the 230 V mains must be made
Warning!
by authorised specialist personnel.
Check the system (roller shutter) regularly for wear
or damage.
The regulations of the local energy supply company
as well as the regulations for wet and damp rooms
according to VDE 0100 must be followed when
making the connections.
Only use unmodified original elero electrical parts.
Keep people away from the system until it is
stationary.
When working on the system (servicing, cleaning
windows etc.), always disconnect it from the mains
supply.
Check the following before installation:
• The drive is only capable of operation as installed.
• Only perform connecting work with the power turned off.
• The blind must be attached to the winding shaft.
• The profile tube must have sufficient clearance from the motor
tube.
• Make sure there is sufficient axial play (1–2 mm)
Installation in profile tubes
X
A
Push drive with relevant adapter
and limit switch into the profile
tube.
Protect the motor cable in order
to avoid it brushing against the
roller shutter. Avoid kinking the
cable.
X
Secure the counterpart support
B
to prevent axial movement,
e.g. screw or rivet on idler.
Secure the drive axially in the
support.
X
C
Attach the blind to the shaft!
Risk of injury due to electrocution.
Warnung!
Do not drill in the area of the motor!
Installation
Warning!
Remove of the motor cable plug
Warning!
A
B
Delivery condition
C
Remove the motor cable plug
Switch off voltage supply.
1. Press locking mechanism on the plug towards the cable using a
screwdriver.
2. Pull out the plug.
Insert the motor cable plug
3. Switch off voltage supply. Insert plug until locking mechanism
engages.
Observe the following installation instructions!
– The drive must be fixed in such a way that it does
not endanger personnel.
– Before installing the drive, all lines and equipment,
which are not required for operation, must be
removed from the site.
– During installation, during operation and when
work is carried out on the system, the option to
separate all three poles from the mains must
always exist (Hirschmann connector and
Hirschmann coupling or a two-pole switch with
minimum 3 mm contact gap or all-pole main
switch).
– If the drive is controlled by a switch with OFF
pre-setting (dead man's button), the momentary
contact switch must be fitted at a height of more
than 1.50 m and separated from the moving parts.
The travel range of the systems must always be
visible during operation.
– Moving parts in a drive, which are below 2.5 m,
must be guarded.
– Set torque and set operating time must be
adapted to the requirements of the product which
is driven.
– Please note the technical data on the type plate.
– Please note that with this drive (type M motor)
the smallest internal tube diameter corresponds
with 46 mm.
– The drive must be installed so that it cannot get
wet.
– Do not install drives in surroundings which are at
risk of explosion or in mobile appliances
(e.g. motor vehicles).
– Keep children away from the (remote) control unit.
Risk of injury due to
electrocution.
When the motor cable plug
is removed the supply line
must be volt free.
Remove plug
1
2
Insert plug
3

Advertisement

loading

Summary of Contents for elero RolTop Series

  • Page 1 – Set torque and set operating time must be Only use unmodified original elero electrical parts. adapted to the requirements of the product which Keep people away from the system until it is is driven.
  • Page 2 Connection/Installation/Commissioning Types of installation Start up Different types of installation are possible: Note: The drive is in commissioning mode when the roller shutters are delivered. Type of installation Possible with 1. Upper/lower limit position T-strap, tapes, freely programmable belt Assembly cable connection 2.
  • Page 3 End position setting Installation Method 1: Upper/lower limit position freely programmable Installation Method 1: Upper/lower limit position freely programmable Note: Ensure that the equipment is correctly connected. STOP 4. Press the DOWN momentary contact switch again. STOP Move the blind down until it is a short distance above the desired lower limit stop.
  • Page 4 End position setting Installation Method 2: Fixed upper stop/lower stop freely adjustable Installation Method 2: Fixed upper stop/ lower stop freely adjustable Note: Ensure that the equipment is correctly connected. STOP 4. Press the DOWN momentary contact switch again. STOP Move the blind down until it is a short distance above the desired lower limit stop.
  • Page 5 End position setting Installation Method 3: Fixed upper and lower stop Installation Method 3: Fixed upper und lower limit stops Note: Ensure that the equipment is correctly connected. STOP 4. Press the DOWN momentary contact switch again. STOP Run the blind until shortly before the lower limit stop. The drive starts up slowly with a short STOP.
  • Page 6 End position setting Installation Method 4: Upper stop freely adjustable/fixed lower stop Installation Method 4: Upper stop freely adjustable/ fixed lower stop Note: Ensure that the equipment is correctly connected. STOP 4. Press the DOWN momentary contact switch again. Run the blind until shortly before the lower limit stop. STOP The drive starts up slowly with a short STOP.
  • Page 7 Changing/Deleting the limit positions Changing/Deleting the limit positions Mains Blue (neutral wire) Black Brown Green-yellow 1. Switch on mains. 2. Move the blind to an intermediate position. approx. 5 sec. 3. Press both momentary contact switches on the assembly cable simultaneously.
  • Page 8: Troubleshooting

    • Travel to limit position/stop too short • Drive has to travel to short STOP Linsenhofer Straße 59–63 Telefon (0 70 25) 13-01 info@elero.de elero GmbH Antriebstechnik D-72660 Beuren Telefax (0 70 25) 13-212 www.elero.com We reserve the right to make technical changes 08/07...