RRU3942&RRU3642
Installation Guide
Recommended Clearances for Three or More RRUs Installed on a Pole
Figure 3-26
mode.
Figure 3-26 Recommended clearances for three or more RRUs installed on a pole
Minimum Clearances for Three or More RRUs Installed on a Pole
Figure 3-27
Issue 07 (2013-12-30)
NOTE
l The recommended clearances ensure normal running and provide an appropriate space for operation
and maintenance (OM). If there is sufficient space, retain the recommended clearances.
l The minimum clearances ensure normal running and heat dissipation but do not allow OM activities
such as checking indicator status and opening the cabling cavity. If the installation space is insufficient,
retain the minimum clearances after the installation.
shows the recommended clearances for multiple RRUs installed in centralized
shows the minimum clearances for multiple RRUs installed in centralized mode.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Information About the Installation
31