Troubleshooting; Frequently Asked Questions - Remington i-LIGHT IPL6750 Manual

Hide thumbs Also See for i-LIGHT IPL6750:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Storage
Switch off the unit, unplug and allow to cool for 10 minutes before storage.

TROUBLESHOOTING

Always read these instructions fully before using i-LIGHT.
Refer to this troubleshooting guide if you experience any problems with i-LIGHT, as this section addresses the most
common problems you could encounter with i-LIGHT. If you have followed the instructions in this section and con-
tinue to experience problems, please contact the Remington® Service Centre for further assistance.
The power switch is ON, but the unit is not working.
Make sure the unit is plugged into a working electrical outlet.
Try switching to a different outlet.
The unit appears to have cracks or is broken.
Do not use if the unit is damaged. If you have concerns about using the unit, discontinue use and contact the Rem-
ington® Service Centre for further assistance.
I have switched the unit ON, but I cannot change the Mode.
Try resetting the unit by turning it off and waiting several seconds before turning it back on.
The Bulb Status Indicator Light turns green but the unit does not flash when the button is pressed.
Make sure the Skin Contact Sensor is in full contact with the skin.
Try resetting the unit by turning it off and waiting several seconds before turning it back on.
There is a strange smell
Be sure the area is completely shaved before treatment.
The treated areas become red after treatment
This is normal and the redness should subside. If not, try using a lower energy level.
BE AWARE: If the unit is used over an extended period of time, the unit might automatically disable
momentarily (estimated 40 seconds) to cool down. Once the unit has cooled down, it will be ready to use again.
All currently selected energy level
indicators flashing.
All energy level indicators flashing.
LED's
All LED's flashing with warning
beep.
Not full contact.
SOUNDS
Replace bulb.
Skin contact sensors stuck.

FREQUENTLY ASKED QUESTIONS

For a full list of FAQs, please visit (www.remington-ilight.com)
Q. What areas of my body can I treat with i-LIGHT?
A. i-LIGHT is designed for unisex use on areas below the neck, including the legs, underarms, bikini line, arms, chest
and back. Females can also use on facial hair below the cheekbone.
Unit is overheated and is disabled momentarily to cool down.
Unit is malfunctioning. Turn the unit off, wait a few moments and
try again. If problem persists, the unit should be returned for
repair.
Treatment head is removed or loose.
Flash button was pressed while the skin contact sensor was not
fully engaged.
Bulb is missing or needs to be replaced.
Flash button was pressed after the skin contact sensor had been
engaged since unit start up. Skin contact sensor may be stuck.
ENGLISH
GB
DE
NL
FR
ES
IT
DK
SE
FI
PT
SK
CZ
PL
HU
RU
TR
RO
GR
SI
HR
UA
AE
11

Advertisement

Table of Contents
loading

Table of Contents