Page 2
SKIN CHART THE SKIN CHART WARNING: i-LIGHT is not suitable for very dark or black skin, white/grey or very light blonde/red hair. DO NOT use on or around the eyes, eyebrows or eyelashes. Doing so can cause serious and permanent eye injury.
Page 3
Thank you for buying your new Remington® product. Please read these instructions carefully and keep them safe. Remove all packaging before use. IMPORTANT SAFETY INSTRUCTIONS 1 WARNING – TO REDUCE THE RISK OF BURNS, ELECTROCUTION, FIRE, OR INJURY TO PERSONS: 2 Use this appliance only for its intended use described in this manual.
Page 5
KEY FEATURES 1 Power Switch 2 Power Inlet 3 Base Unit 4 Hand Piece 5 Flash Button 6 Energy Level Selection Button 7 Cool Down Mode Indicator 8 Bulb Status Indicator Display 9 Energy Level Indicator 10 Skin Tone Sensor 11 Hand Piece Cord 12 Flash Window 13 Skin Contact Sensors...
Page 6
GETTING ACQUAINTED WITH i-LIGHT , What is i- LIGHT ? The i- LIGHT system is a revolutionary light-based device designed for the removal of unwanted body hair at home. i- LIGHT utilises similar clinically-proven technology that professional dermatologists and salons use, optimised for personal treatment.
Page 7
Hair grows in a cycle of 3 different phases which lasts 18-24 months (Fig. 3). Only hairs in the active growth phase are susceptible to treatment, which is why multiple treatments are required for optimal results. Fig. 3 Active Growth Fig.
Page 8
, Areas not to treat: • Do not use on the scalp or ears. • Do not use on the face or neck. • Do not use on nipples, areola or genitals. • Do not use if you have tattoos or permanent makeup in the area to be treated. • Do not use on dark brown or black spots such as moles, birth marks or freckles. • Do not use on an area of recent surgery, deep peel, laser resurfacing, scars or skin that has been damaged with burns or scalds. , When not to use/When to avoid using i-LIGHT • DO NOT use if you have tanned skin in the intended treatment area, as your skin may be too dark and treatment in tanned areas could temporarily cause skin swelling, blisters, or could change the colour of your skin. Wait until your tan has faded before treating. ...
• Do not use over or near anything artificial such as silicon implants, Implanon contraceptive implants, pacemakers, subcutaneous injection ports (insulin dispenser) or piercings. • Wireless communications equipment may affect the i-LIGHT device and should be kept at least 3.3 m away. PREPARING FOR USE , Familiarise yourself with the features of your new i-LIGHT device. , Flash Window with built-in UV skin protection •...
Page 10
, Skin Tone Sensor • Will only allow usage on suitable skin tones. , CHECK YOUR SKIN TONE • Consult the skin and hair chart at the front of this manual to ensure your skin is in the suitable range and your hair colour is susceptible to treatment with i-LIGHT.
Page 11
• Connect the power cord to the wall outlet. Turn the power switch ON. (fig. 5) Fig. 5 , SELECTING THE ENERGY LEVEL • The i-LIGHT is equipped with 5 energy levels. Level 1 is the lowest setting and level 5 is the highest setting. , TIP: For the most effective results, always use the highest energy level that does not cause discomfort on the skin.
Page 12
Fig. 7 3 Press the Flash Button to deliver a flash. • Mild to moderate discomfort is normal. If a flash delivered at Energy Level 1 feels tolerable, increase to Energy Level 2. Move the device to a different spot and flash the i-LIGHT one more time. Repeat this process until you find the setting that feels right for you. • Wait 24 hours and then look at the test area. If the skin appears normal, proceed with your first full treatment at the energy level you determined is right for you.
Page 13
The infinity bulb means no replacement parts are needed. • The bulb in this device is guaranteed to last for the entire guarantee period as communicated on the guarantee card supplied with this product. • In the extremely unlikely event that your bulb becomes empty, please contact your local Remington Service centre who will provide you with a replacement. , Signs that the bulb needs replacing: • Bulb Status Indicator is illuminated yellow: 150 Flashes remain in the bulb • Bulb status indicator is flashing yellow: Bulb is empty.
• Refer to this troubleshooting guide if you experience any problems with i-LIGHT, as this section addresses the most common problems you could encounter with i-LIGHT. If you have followed the instructions in this section and continue to experience problems, please contact the Remington® Service Centre for further assistance. , The power switch is ON, but the unit is not working.
Page 15
• Be sure the area is completely shaved before treatment. , The treated areas become red after treatment. • This is normal and the redness should subside. If not, try using a lower energy level. , BE AWARE: If the unit is used over an extended period of time, the unit might automatically disable momentarily (estimated 40 seconds) to cool down. Once the unit has cooled down, it will be ready to use again.
Skin contact sensor may be stuck. FREQUENTLY ASKED QUESTIONS • For a full list of FAQs, please visit (www.remington-ilight.com) Q. What areas of my body can I treat with i-LIGHT? A. i-LIGHT is designed for unisex use on areas below the neck, including the legs, underarms, bikini line, arms, chest and back.
Page 17
If you call the Service Centre, please have the Model No. to hand, as we won’t be able to help you without it. The Model No. can be found on the rating plate of the appliance. Replacement parts and accessories are available to buy at www.remington.co.uk/parts-accessories...
Page 20
Unit B12, Ballymount Corporate Park, Ballymount, Dublin 12. www.remington.co.uk Model No. IPL6250 14/UK/ IPL6250 T22-0002737 Version 08 / 14 Remington® is a Registered Trade Mark of Spectrum Brands, Inc., or one of its subsidiaries. Spectrum Brands (UK) Ltd Fir Street, Failsworth, Manchester M35 0HS www.remington.co.uk...
Need help?
Do you have a question about the IPL6250 and is the answer not in the manual?
Questions and answers