17.2.2
Operation mode during Heating Only Operation
The table below shows the operation mode comparison when Heating Only Operation Mode Activated and
Deactivated.
Operation Mode
AUTO
HEAT
COOL
DRY
NANOE Stand-alone
Force Cooling
Force Heating
AUTO (with Timer)
HEAT (with Timer)
COOL (with Timer)
DRY (with Timer)
Cooling Test Mode
Heating Test Mode

17.3 Remote Control Button

17.3.1
SET Button
To check remote control transmission code and store the transmission code to EEPROM:
Press "Set" button by using pointer.
o
Press "Timer Set" button until a "beep" sound is heard as confirmation of transmission code changed.
o
To limit set temperature range for COOL & DRY, HEAT mode.
Press "Set" button by using pointer.
o
Press TEMP increment or decrement button to choose No. 3.
o
Press Timer increment or decrement button to select desired temperature low limit of set temperature for
o
COOL & DRY mode.
Press Timer Set button to confirm low limit selection.
o
Press TEMP increment or decrement button to choose No. 4.
o
Press Timer decrement or increment button to select desired temperature high limit of set temperature for
o
COOL & DRY mode.
Press Timer Set button to confirm high limit selection.
o
Press TEMP increment or decrement button to choose No. 5.
o
Press Timer increment or decrement button to select desired temperature low limit of set temperature for
o
HEAT mode.
Press Timer Set button to confirm low limit selection.
o
Press TEMP increment or decrement button to choose No. 6.
o
Press Timer decrement or increment button to select desired temperature high limit of set temperature for
o
HEAT mode.
Press Timer Set button to confirm high limit selection.
o
LCD returns to original display if remote control does not operate for 30 seconds or press Timer Cancel
o
button.
Heating Only Operation Mode Activated
After 30s sampling, regardless of the indoor intake or
outdoor intake temperature judgment, the unit will run
Heating operation.
The unit will run Heating operation.
The unit will stop and Power LED blinking.
The unit will stop and Power LED blinking.
The unit will stop and Power LED blinking.
The unit will run Force Cooling Operation for
X_CTRYTM [15] minutes
The unit will run Force Heating operation.
The unit will turn ON by the timer and run Auto
Operation. After 30s sampling, regardless of the
indoor intake or outdoor intake temperature judgment,
the unit will run Heating operation.
The unit will turn ON by the timer and run Heating
Operation.
The unit will not turn ON by the timer. Power LED
blinking.
The unit will not turn ON by the timer. Power LED
blinking.
The unit will stop and Power LED blinking.
The unit will operate according to specify Heating test
mode operation parameter.
Heating Only Operation Mode Deactivated
After 30s sampling, the unit will judge the operation
mode base on remote controller temperature setting
and Indoor Intake Sensor (New Auto Mode) or
Outdoor Intake Sensor (Old Auto Mode).
The unit will run Heating operation.
The unit will run Cooling operation.
The unit will run Cooling Dry operation.
The unit will run Nanoe Stand-alone operation.
The unit will run Force Cooling operation.
The unit will run Force Heating operation.
The unit will turn ON by the timer and run Auto
Operation. After 30s sampling, the unit will judge the
operation mode base on remote controller
temperature setting and Indoor Intake Sensor (New
Auto Mode) or Outdoor Intake Sensor (Old Auto
Mode).
The unit will turn ON by the timer and run Heating
Operation.
The unit will turn ON by the timer and run Cooling
Operation.
The unit will turn ON by the timer and run Cooling Dry
Operation.
The unit will operate according to specify Cooling test
mode operation parameter.
The unit will operate according to specify Heating test
mode operation parameter.
86