TEMPERATURE UNIT SUBMENU:
Press d
Press b
Press d
FILTER CONSTANT SUBMENU:
Press d
Press b
Press d
8) Display flashes previous Temperature Unit selection.
9) Scroll though the available selections to the Temperature Unit
of your choice: °F or °C .
10) Display shows STRD stored message momentarily and then
advances to FLTR Filter Constant.
11) Display flashes previous selection for Filter Constant.
12) Scroll though the available selections:
0001 , 0002 , 0004 , 0008 , 0016 , 0032 , 0064 , 0128
13) Display shows STRD stored message momentarily only, if
change were made, otherwise press a to advance to the next
menu.
If Process was selected in the Input Type Menu the display will
advance to IN.RD Input/Reading Submenu, otherwise the
display advances to the ALR1 Alarm 1 Menu.
The Filter Constant Submenu allows the user to specify the
number of readings stored in the Digital Averaging Filter. A filter
value of 2 is approximately equal to 1 second RC low pass time
constant.