DeDietrich Innovens MCA 25 BIC User Manual page 40

Wall-hung gas condensing boilers
Table of Contents

Advertisement

6. Troubleshooting
Code Faults
D15
ST.TANK S.FAIL
D16
SWIM.P.B. S.FAIL
D16
SWIM.P.C. S.FAIL
D17
DHW 2 S.FAIL
D27
PCU COM. FAIL
D32
5 RESET:ON/OFF
D37
TA-S SHORT-CIR
D38
TA-S DISCONNEC
D99
DEF.BAD PCU
39
Cause
Description
of the
fault
SCU
Storage tank sensor fault
Note:
The hot water storage tank reheating
operation is no longer assured.
SCU
Swimming pool sensor fault circuit B
Swimming pool sensor fault circuit C
Note:
Swimming pool reheating is always
done during the circuit's comfort
period.
SCU
Sensor fault tank 2
SCU
Communication failure between the SCU and PCU PCBs
Contact the professional who takes care of maintenance of the appliance
4
SCU
5 resets done in less than an hour
Switch the boiler off and switch back on
4
If the boiler does not start after several resets (5 attempts possible), contact your
4
heating engineer and inform him of the error message displayed
SCU
The Titan Active System® is short-circuited
Contact the professional who takes care of maintenance of the appliance
4
Remarks:
Domestic hot water production has stopped but can nonetheless be restarted using key
r.
The tank is no longer protected.
If a tank without Titan Active System® is connected to the boiler,check that the TAS
simulation connector (delivered with package AD212) is fitted to the sensor card.
SCU
The Titan Active System® is on an open circuit
Contact the professional who takes care of maintenance of the appliance
4
Remarks:
Domestic hot water production has stopped but can nonetheless be restarted using key
r.
The tank is no longer protected.
If a tank without Titan Active System® is connected to the boiler,check that the TAS
simulation connector (delivered with package AD212) is fitted to the sensor card.
SCU
The SCU software version does not recognise the PCU connected
Contact the professional who takes care of maintenance of the appliance
4
Checking / solution
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
15/06/12 - 300022162-001-01
MCA 25/28 BIC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Innovens mca 28 bic

Table of Contents