6. Troubleshooting
Code Faults
BURNER FAILURE PCU
L14
L16
PARASIT FLAME
L17
VALVE FAIL
L34
FAN FAILURE
L35
BACK>BOIL FAIL
L36
I-CURRENT FAIL
L37
SU COM.FAIL
L38
PCU COM.FAIL
L39
BL OPEN FAIL
37
Cause
Description
of the
fault
5 burner start-up failures
PCU
Detection of a parasite flame
PCU
Problem on the SU PCB
PCU
The fan is not running at the right
speed
PCU
Flow and return reversed
PCU
The flame went out more than 5
times in 24 hours while the burner
was operating
PCU
Communication failure with the SU
PCB
PCU
Communication failure between the
PCU and SCU PCBs
PCU
The BL inlet opened for a short time Bad connection
Checking / solution
No ignition
Contact the professional who takes care of
4
maintenance of the appliance
Ignition arc, but no flame formation
Check that the gas valve is fully opened
4
Contact the professional who takes care of
4
maintenance of the appliance
Presence of the flame but insufficient ionization
(<3 µA)
Check that the gas valve is fully opened
4
Contact the professional who takes care of
4
maintenance of the appliance
Ionization current present when there should not
be a flame
Ignition transformer defective
Gas valve defective
The burner remains very hot: CO
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
SU PCB faulty
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Fan defective
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Sensor fault
Contact the professional who takes care of
4
maintenance of the appliance
Water circulation direction reversed
Check the circulation (direction, pump,
4
valves)
No ionization current
Check that the gas valve is fully opened
4
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
Contact the professional who takes care of
4
maintenance of the appliance
Bad connection
SCU PCB not connected or faulty
Contact the professional who takes care of
4
maintenance of the appliance
External cause
Parameter incorrectly set
Contact the professional who takes care of
4
maintenance of the appliance